Version 1.5.0

Product list

Released in October 2018
Product Version
HULFT IoT Manager 1.5.0
HULFT IoT Agent 1.5.0
HULFT for Windows 8.1.4
HULFT for Linux 8.1.2

Added features

For details on each added feature, see the relevant topic from the links of the management numbers below.

HULFT IoT Manager and HULFT IoT Agent

Management number Brief description Version when it was added
HIPJ-1307 An available format of the product media is added 1.5.0
HIPJ-699 HULFT over TLS is added 1.5.0

Improved features

For details on each improved feature, see the relevant topic from the links of the management numbers below.

HULFT IoT Manager

Management number

Brief description

Version when it was improved

HIPJ-1367

Parameters that are unnecessary or do not return any value are deleted from the REST API

1.5.0

HIPJ-1354

Installer options of HULFT IoT Manager for Linux are changed

1.5.0

HIPJ-1321

Usage that is displayed by the installer of HULFT IoT Manager for Linux is improved

1.5.0

HIPJ-1319

The installer screen is improved

1.5.0

HIPJ-1318

Log messages are improved

1.5.0

HIPJ-1312

JRE 8 is removed from the necessary software

1.5.0

HIPJ-1311

The installation module of HULFT IoT Manager for Windows is changed to ZIP format

1.5.0

HIPJ-1308

The directory structure of the product media is revised

1.5.0

HULFT IoT Agent

Management number

Brief description

Version when it was improved

HIPJ-1426

Windows service name of HULFT IoT Agent for Windows is variable

1.5.0

HIPJ-1253

The user experience for introduction is improved

1.5.0

Issues

For details on each issue, see the relevant topic from the links of the management numbers below.

HULFT IoT Manager

Management number

Brief description

Affected versions

Version when it was corrected

HIPJ-1574

The registered job might not run

1.1.0 - 1.4.1

1.5.0

HIPJ-1502

Backup of PostgreSQL may fail when the user updates HULFT IoT Manager

1.3.0 - 1.4.1

1.5.0

HIPJ-1404

Services of HULFT IoT Manager for Windows might not start

1.2.0 - 1.4.1

1.5.0

HIPJ-1375

A login user who has an admin privilege cannot change own password

1.4.0 - 1.4.1

1.5.0

HULFT IoT Agent

Management number

Brief description

Affected versions

Version when it was corrected

HIPJ-1559

In the Windows environment, when 2,147,483 seconds (approximately 24.8 days) elapses after OS starts, HULFT IoT Agent might continuously execute file triggers and polling processing without waiting time

1.0.0 - 1.4.1

1.5.0

HIPJ-1512

HULFT IoT Agent might fail to register the log to HULFT IoT Manager and it cannot record logs anymore

1.0.0 - 1.4.1

1.5.0

HIPJ-1274

If HULFT IoT Agent fails to establish a connection to HULFT at a start of file transfer, HULFT IoT Agent might not perform according to the "Connection retry count" that you set by using Operation Settings

1.0.0 - 1.4.1

1.5.0

HIPJ-1273

HULFT IoT Agent might execute a send processing of log information to HULFT IoT Manager every second

1.4.0 - 1.4.1

1.5.0

Compatibilities

This section lists incompatibilities between the old product and the new product, which are brought by newly supported functions.

For details on each incompatibility, see the relevant topic from the links of the management numbers below.

HULFT IoT Manager

Management number

Brief description

Affected versions

Version when it was revised

HIPJ-1397

Deletion of the API URLs that are used only for keeping compatibility

1.4.0 - 1.4.1

1.5.0

HIPJ-1367

Deletion of the parameters that are used only for keeping compatibility

1.4.0 - 1.4.1

1.5.0

HIPJ-1354

Change of installation parameters for Linux from capital letter to small letter

1.3.0 - 1.4.1

1.5.0

HULFT IoT Agent

Management number

Brief description

Affected versions

Version when it was revised

HIPJ-1253

Starting Agent just after installation with default settings

1.0.0 - 1.4.1

1.5.0