Version 2.0.0
[Document Revision History]
Date of Issue |
Description |
---|---|
May 8, 2020 |
|
July 3, 2019 |
Published the 1st edition |
Product list
Product |
Version |
---|---|
HULFT IoT Manager |
2.0.0 |
HULFT IoT Agent |
2.0.0 |
HULFT IoT EdgeStreaming |
2.0.0 |
HULFT for Windows |
8.1.4 |
HULFT for Linux |
8.1.2 |
Added features
For details on each added feature, see the relevant topic from the links of the management numbers below.
HULFT IoT EdgeStreaming
Management number |
Brief description |
Version when it was added |
---|---|---|
Release of HULFT IoT EdgeStreaming |
2.0.0 |
Improved features
For details on each improved feature, see the relevant topic from the links of the management numbers below.
HULFT IoT Manager and HULFT IoT Agent
Management number |
Brief description |
Version when it was improved |
---|---|---|
Usage of HULFT IoT in the environment using an SSL accelerator |
2.0.0 |
HULFT IoT Manager
Management number |
Brief description |
Version when it was improved |
---|---|---|
Manager operation improvement when the number of tasks in the Receive Task Queue is maximum |
2.0.0 |
HULFT IoT Agent
Management number |
Brief description |
Version when it was improved |
---|---|---|
Dividing the output directory for the Agent system files and the temporary storage directory for the log files |
2.0.0 |
Issues
For details on each issue, see the relevant topic from the links of the management numbers below.
HULFT IoT Manager
Management number |
Brief description |
Affected versions |
Version when it was corrected |
---|---|---|---|
Resources will leak when Manager refers to the product information |
1.0.0 - 1.5.0 |
2.0.0 |
|
Even if the product key update failed, the screen might show as if the product key is updated correctly. |
1.3.0 - 1.5.0 |
2.0.0 |
|
If HULFT fails to start while the user is installing HULFT IoT Manager, the installation fails. |
1.1.0 - 1.5.0 |
2.0.0 |
|
Files can be distributed to the HULFT IoT Agent instance whose status is "Standby". |
1.1.0 - 1.5.0 |
2.0.0 |
|
The deletion of HULFT IoT Agent might fail |
1.1.0 - 1.5.0 |
2.0.0 |
|
When the users update HULFT IoT Manager, if the application.properties file includes commented out lines, HULFT IoT Manager may convert only the rows that are commented out. |
1.4.0 - 1.5.0 |
2.0.0 |
|
The file upload to HULFT IoT Manager might fail. |
1.0.0 - 1.5.0 or 1.1.0 - 1.5.0 |
2.0.0 |
|
If the value of the particular items in a transfer log includes one or more commas, HULFT IoT Manager cannot register transfer logs that HULFT IoT Agent output. |
1.4.0 - 1.5.0 |
2.0.0 |
|
Next Scheduled Sync Time might show the later time than the intended schedule. |
1.0.0 - 1.5.0 |
2.0.0 |
|
The Change Profile screen might show the unintended profile. |
1.0.0 - 1.5.0 |
2.0.0 |
|
HULFT IoT Manager might fail an API authentication. |
1.3.0 - 1.5.0 |
2.0.0 |
|
When the incorrect value is set to the register a whitelist entry API function, the returned HTTP status code is not appropriate. |
1.0.0 - 1.5.0 |
2.0.0 |
|
The logs other than the target of truncation might be deleted by using the log truncation function. |
1.0.0 - 1.5.0 |
2.0.0 |
Compatibilities
This section lists incompatibilities between the old product and the new product, which are brought by newly supported functions.
For details on each incompatibility, see the relevant topic from the links of the management numbers below.
HULFT IoT Manager
Management number |
Brief description |
Affected versions |
Version when it was revised |
---|---|---|---|
Change of the response operation if Manager failed to connect the database |
1.0.0~1.5.0 |
2.0.0 |
|
Change of names and notation for distribution file size in environment settings file |
1.0.0~1.5.0 |
2.0.0 |