Official | HULFT IoT EdgeStreaming Adapter Reference First Edition: July 1, 2021
USB connection settings
Configure USB connection settings.
To display the settings screen, click Add either in the pulldown list under Destination on the receive operation screen, or in Resource list on the Edit resource list screen.
For details on the receive operation screen, refer to Receive.
For details on the editing screen for the resource list, refer to Edit resource list.

Figure 7.7 USB connection settings screen
(1) Field list
This is a list of the fields to configure on the USB connection settings screen.
Field Name |
Initial Value |
Setting Value |
Omission |
Notes |
|
---|---|---|---|---|---|
Name |
|
Single-byte alphanumeric characters and certain symbols (*1) |
- |
A value that begins with a single-byte alphabetic character |
|
Required settings |
|||||
|
Vendor |
|
|
- |
|
Product |
|
|
- |
|
|
Configuration No |
|
From 0 to 2147483646 |
- |
Set as integer |
|
Interface No |
|
From 0 to 2147483646 |
- |
Set as integer |
|
Alternate No |
|
From 0 to 2147483646 |
- |
Set as integer |
|
Endpoint No |
|
From 0 to 2147483646 |
- |
Set as integer |
- |
: |
Impossible to omit |
*1 |
: |
Only "_" (underscore) can be specified. |
(2) Description of each field
This section explains each of the fields to configure on the USB connection settings screen.
After changing these settings, click Finish to save the settings.
Click Cancel to discard the changes.
- Name
-
Name of the USB connection settings component
Single-byte alphanumeric characters and "_" (underscore) can be used.
Use a value that begins with a single-byte alphabetic character.
Required settings
- Vendor
-
VendorID for the USB device
Specify VendorID.
For details on VendorID, refer to the specifications of the USB device that you specified as the connection destination.
- Product
-
ProductID for the USB device
Specify ProductID.
For details on ProductID, refer to the specifications of the USB device that you specified as the connection destination.
- Configuration No
-
ConfigurationNumber for the USB device
Specify ConfigurationNumber.
For details on ConfigurationNumber, refer to the specifications of the USB device that you specified as the connection destination.
- Interface No
-
InterfaceNumber for the USB device
Specify InterfaceNumber.
For details on InterfaceNumber, refer to the specifications of the USB device that you specified as the connection destination.
- Alternate No
-
AlternateNumber for the USB device
Specify AlternateNumber.
For details on AlternateNumber, refer to the specifications of the USB device that you specified as the connection destination.
- Endpoint No
-
EndpointNumber for the USB device
Specify EndpointNumber.
For details on EndpointNumber, refer to the specifications of the USB device that you specified as the connection destination.
Official | HULFT IoT EdgeStreaming Adapter Reference First Edition: July 1, 2021