Official | HULFT IoT EdgeStreaming Adapter Reference First Edition: July 1, 2021

Edit resource list

Edit the resource list.

On the Required settings tab on the receive operation screen, open the pulldown list of Destination, and then click Edit resource list to display the editing screen.

For details on the receive operation screen, refer to Receive.

 

Figure 7.8 Edit resource list screen

(1) Field list

This is a list of the fields to configure on the Edit resource list screen.

Table 7.10 Field list

Field Name

Initial Value

Setting Value

Omission

Notes

Resource list

 

Resource name for registered USB connection

-

 

Name

 

Single-byte alphanumeric characters and certain symbols (*1)

-

A value that begins with a single-byte alphabetic character

Required settings

 

Vendor

 

 

-

 

Product

 

 

-

 

Configuration No

 

From 0 to 2147483646

-

Set as integer

Interface No

 

From 0 to 2147483646

-

Set as integer

Alternate No

 

From 0 to 2147483646

-

Set as integer

Endpoint No

 

From 0 to 2147483646

-

Set as integer

-

:

Impossible to omit

*1

:

Only "_" (underscore) can be specified.

(2) Description of each field

This section explains each of the fields to configure on the Edit resource list screen.

After changing these settings, click Apply to save the settings.

Click Cancel to discard the changes.

Click Close to close the screen.

Resource list

Resource list for USB connection

To edit the content of the settings, select the resource name of a registered USB connection.

When you select a resource name, the registered contents are displayed.

When you click Add, the USB connection settings screen appears, and you can add resource information.

For details on the USB connection settings screen, refer to USB connection settings.

When you click Delete, the resource information of the selected USB connection settings is deleted.

Name

Name of the USB connection settings component

Single-byte alphanumeric characters and "_" (underscore) can be used.

Use a value that begins with a single-byte alphabetic character.

Required settings

Vendor

VendorID for the USB device

Specify VendorID.

For details on VendorID, refer to the specifications of the USB device that you specified as the connection destination.

Product

ProductID for the USB device

Specify ProductID.

For details on ProductID, refer to the specifications of the USB device that you specified as the connection destination.

Configuration No

ConfigurationNumber for the USB device

Specify ConfigurationNumber.

For details on ConfigurationNumber, refer to the specifications of the USB device that you specified as the connection destination.

Interface No

InterfaceNumber for the USB device

Specify InterfaceNumber.

For details on InterfaceNumber, refer to the specifications of the USB device that you specified as the connection destination.

Alternate No

AlternateNumber for the USB device

Specify AlternateNumber.

For details on AlternateNumber, refer to the specifications of the USB device that you specified as the connection destination.

Endpoint No

EndpointNumber for the USB device

Specify EndpointNumber.

For details on EndpointNumber, refer to the specifications of the USB device that you specified as the connection destination.

 

 

Official | HULFT IoT EdgeStreaming Adapter Reference First Edition: July 1, 2021