Official | HULFT IoT EdgeStreaming Adapter Reference First Edition: July 1, 2021
Edit resource list
Edit the resource list.
On the Required settings tab on the receive operation screen, open the pulldown list of Destination, and then click Edit resource list to display the editing screen.
For details on the receive operation screen, refer to Receive.

Figure 7.8 Edit resource list screen
(1) Field list
This is a list of the fields to configure on the Edit resource list screen.
Field Name |
Initial Value |
Setting Value |
Omission |
Notes |
|
---|---|---|---|---|---|
Resource list |
|
Resource name for registered USB connection |
- |
|
|
Name |
|
Single-byte alphanumeric characters and certain symbols (*1) |
- |
A value that begins with a single-byte alphabetic character |
|
Required settings |
|||||
|
Vendor |
|
|
- |
|
Product |
|
|
- |
|
|
Configuration No |
|
From 0 to 2147483646 |
- |
Set as integer |
|
Interface No |
|
From 0 to 2147483646 |
- |
Set as integer |
|
Alternate No |
|
From 0 to 2147483646 |
- |
Set as integer |
|
Endpoint No |
|
From 0 to 2147483646 |
- |
Set as integer |
- |
: |
Impossible to omit |
*1 |
: |
Only "_" (underscore) can be specified. |
(2) Description of each field
This section explains each of the fields to configure on the Edit resource list screen.
After changing these settings, click Apply to save the settings.
Click Cancel to discard the changes.
Click Close to close the screen.
- Resource list
-
Resource list for USB connection
To edit the content of the settings, select the resource name of a registered USB connection.
When you select a resource name, the registered contents are displayed.
When you click Add, the USB connection settings screen appears, and you can add resource information.
For details on the USB connection settings screen, refer to USB connection settings.
When you click Delete, the resource information of the selected USB connection settings is deleted.
- Name
-
Name of the USB connection settings component
Single-byte alphanumeric characters and "_" (underscore) can be used.
Use a value that begins with a single-byte alphabetic character.
Required settings
- Vendor
-
VendorID for the USB device
Specify VendorID.
For details on VendorID, refer to the specifications of the USB device that you specified as the connection destination.
- Product
-
ProductID for the USB device
Specify ProductID.
For details on ProductID, refer to the specifications of the USB device that you specified as the connection destination.
- Configuration No
-
ConfigurationNumber for the USB device
Specify ConfigurationNumber.
For details on ConfigurationNumber, refer to the specifications of the USB device that you specified as the connection destination.
- Interface No
-
InterfaceNumber for the USB device
Specify InterfaceNumber.
For details on InterfaceNumber, refer to the specifications of the USB device that you specified as the connection destination.
- Alternate No
-
AlternateNumber for the USB device
Specify AlternateNumber.
For details on AlternateNumber, refer to the specifications of the USB device that you specified as the connection destination.
- Endpoint No
-
EndpointNumber for the USB device
Specify EndpointNumber.
For details on EndpointNumber, refer to the specifications of the USB device that you specified as the connection destination.
Official | HULFT IoT EdgeStreaming Adapter Reference First Edition: July 1, 2021