List of Error Codes for Logs
E100001
- Description:
-
Failed to read the Agent configuration file ({0}).
- Measure:
-
Check the content of the Agent configuration file.
E100003
- Description:
-
The file transfer was canceled. The version of the connected HULFT is not supported. {0}
- Measure:
-
To use HULFT-WebConnect, a version of HULFT that is supported must be used.
E100004
- Description:
-
Failed in the send processing. An error might occur in the network.
- Measure:
-
Check the network environment to see if there are any problems with the connection to the HULFT-WebConnect service. If connecting via the proxy server, check the fields under 'Proxy Information Settings' in the Agent configuration file.
E100005
- Description:
-
Failed to start Agent as a daemon.
- Measure:
-
Use the Agent status confirmation command to check the status and then restart Agent.
E100006
- Description:
-
Failed to obtain the list of access points. Starting Agent is canceled.
- Measure 1:
-
Register the following value for 'service.accesspoint' in the Agent configuration file:
-
service-ap.tokyo.webconnect.hulft.com
-
- Measure 2:
-
Check the network environment to see if there are any problems with the connection to the HULFT-WebConnect service. If connecting via the proxy server, check the fields under 'Proxy Information Settings' in the Agent configuration file.
E100008
- Description:
-
Failed to obtain the host information of the connection destination service. Starting Agent is canceled.
- Measure:
-
Check the network environment to see if there are any problems with the connection to the HULFT-WebConnect service. If connecting via the proxy server, check the fields under 'Proxy Information Settings' in the Agent configuration file.
E100009
- Description:
-
The receiving port is already in use by the other processes. Starting Agent is canceled. PortNo.:[{0}]
- Measure:
-
Check the value that you registered for 'agent.sender.port' in the Agent configuration file and perform one of the following:
-
Register a port number that is not in use.
-
Assign a different port number to the other application or process that is using the port number.
-
E100010
- Description:
-
The Agent configuration file is invalid. [{0}]
- Measure:
-
Check the content that you registered in the Agent configuration file.
E100012
- Description:
-
Failed in the internal communication.
- Measure:
-
Use the Agent status confirmation command to check the status and then restart Agent by restarting the service or by using the Agent startup command.
E100014
- Description:
-
The file transfer was canceled. The receiving-side Agent is not connected. {0}
- Measure:
-
Check the network environment to see if there are any problems with the connection to the HULFT-WebConnect service and then restart the receiving-side Agent.
E100015
- Description:
-
The file transfer was canceled. The relay authorization is not set on the sending side. {0}
- Measure:
-
Use Management Console to check whether the Connection ID of the receiving side is authorized in the Relay Authorization Settings on the sending side.
E100016
- Description:
-
The file transfer was canceled. The Relay Authorization Settings are disabled on the sending side. {0}
- Measure:
-
Check whether the Relay Authorization Settings on the sending side are enabled on Management Console.
E100017
- Description:
-
The file transfer was canceled. The relay authorization is not set on the receiving side. {0}
- Measure:
-
Use Management Console to check whether the Connection ID of the sending side is authorized in the Relay Authorization Settings on the receiving side.
E100018
- Description:
-
The file transfer was canceled. The Relay Authorization Settings are disabled on the receiving side. {0}
- Measure:
-
Check whether the Relay Authorization Settings on the receiving side are enabled on Management Console.
E100019
- Description:
-
Failed to connect to the receiving-side HULFT. {0}
- Measure:
-
Check the status of HULFT on the receiving side.
E100020
- Description:
-
Failed to establish the transfer session by the receiving-side Agent. {0}
- Measure:
-
Check the network environment to see if there are any problems with the connection to the HULFT-WebConnect service.
E100021
- Description:
-
Failed to establish the transfer route. Code:[{0}], {1}
- Measure:
-
Check the network environment to see if there are any problems with the connection to the HULFT-WebConnect service.
E100022
- Description:
-
The protocol version that does not support the relay transfer was detected. When you transfer the file from HULFT Ver.8.0 to HULFT Ver.7, enable ''HULFT7 Comm. Mode'' in the Host Information of the sending-side HULFT. {0}
- Measure:
-
When you transfer files from HULFT Ver.8.0 to HULFT Ver.7, enable 'HULFT7 Comm. Mode' in the Host Information on HULFT Ver.8.0.
E100023
- Description:
-
The specified Connection ID authentication settings file is not found. File:[{0}]
- Measure:
-
Check whether the Connection ID authentication settings file exists.
E100024
- Description:
-
Failed to read the specified Connection ID authentication settings file. File:[{0}]
- Measure:
-
Check the content of the Connection ID authentication settings file.
E100025
- Description:
-
The registered information does not exist in the Connection ID authentication settings file. File:[{0}]
- Measure:
-
Check whether the Connection ID is registered in the Connection ID authentication settings file.
E100026
- Description:
-
The number of entries registered in the Connection ID authentication settings file exceeds the upper limit. File:[{0}]
- Measure:
-
Reduce the number of Connection IDs registered in the Connection ID authentication settings file to 999 or less.
E100027
- Description:
-
The Connection ID authentication settings file is invalid. [{0}]
- Measure:
-
Check the content that you registered in the Connection ID authentication settings file.
E100028
- Description:
-
The duplicated Connection IDs were detected in the Connection ID authentication settings file. [{0}]
- Measure:
-
Confirm that there are no duplicated Connection IDs registered in the Connection ID authentication settings file.
E100029
- Description:
-
A transfer error was received from the service. Code:[{0}], {1}
- Measure:
-
Check the network environment to see if there are any problems with the connection to the HULFT-WebConnect service.
E100030
- Description:
-
The Connection ID authentication settings file contains the Connection ID that was registered with the different account. File: [{0}]
- Measure:
-
Check the Connection ID that you registered in the Connection ID authentication settings file.
E100032
- Description:
-
The Trial version license is expired. [{0}]
- Measure:
-
The Trial version license has expired. If you want to continue using HULFT-WebConnect, purchase and apply a Product version license.
E100034
- Description:
-
If the license is not registered, the service cannot be used. Register the license on the HULFT-WebConnect Management Console. [{0}]
- Measure:
-
Your Product version license has expired or is in violation of its terms. Register a valid Product version license.
E100035
- Description:
-
The relay transfer was canceled. The remote Agent is not connected. {0}
- Measure:
-
Check the status of the remote Agent.
E100036
- Description:
-
Failed to connect to the remote HULFT. {0}
- Measure:
-
Check the status of the remote HULFT.
E100037
- Description:
-
Failed to establish the transfer session by the remote Agent. {0}
- Measure:
-
Check the network environment to see if there are any problems with the connection to the HULFT-WebConnect service.
E100038
- Description:
-
Agent was not authenticated within a specified period of time. Starting Agent is canceled.
- Measure:
-
Check the network environment to see if there are any problems with the connection to the HULFT-WebConnect service and then restart Agent.
E100039
- Description:
-
Agent did not start within a specified period of time. Starting Agent is canceled.
- Measure:
-
Check the network environment to see if there are any problems with the connection to the HULFT-WebConnect service and then restart Agent.
E100040
- Description:
-
The Connection ID does not exist. {0}
- Measure:
-
Check whether the Connection ID of the sending side is registered in the Connection Settings on Management Console.
E100041
- Description:
-
Failed to establish the transfer session by the remote Agent due to IP filter setting. {0}
- Measure:
-
Check the IP filter registered in the Connection Settings of the receiving side on Management Console.
E100047
- Description:
-
The total amount of the data transferred in this month exceeded the limit of the Trial version. {0}
- Measure:
-
If the expiration date of the Trial version license is next month or after, transfer the file again next month or after. If the expiration date is within the current month, purchase and apply the Product version license.
E110003
- Description:
-
The sending-side Agent is already running.
- Measure:
-
Terminate the sending-side Agent that is running and then restart the sending-side Agent.
E110006
- Description:
-
The connection from the sending-side Agent was not authenticated by the service. Confirm whether the contents of the Connection ID authentication settings file are correct or not. {0}
- Measure:
-
Check the Connection ID and the Connection Password that you registered in the Connection ID authentication settings file.
E110007
- Description:
-
Failed to connect to the service from the sending-side Agent.
- Measure:
-
Check the network environment to see if there are any problems with the connection to the HULFT-WebConnect service. If connecting via the proxy server, check the fields under 'Proxy Information Settings' in the Agent configuration file.
E110008
- Description:
-
Failed to start the TCP server.
- Measure:
-
Use the Agent status confirmation command to check the status and then restart the sending-side Agent.
E110011
- Description:
-
Authentication of the transfer session failed.
- Measure:
-
Check the network environment to see if there are any problems with the connection to the HULFT-WebConnect service. If connecting via the proxy server, check the fields under 'Proxy Information Settings' in the Agent configuration file.
E110016
- Description:
-
An error occurred during the communication with the sending-side HULFT. Cause:[{0}], Message:[{1}]
- Measure:
-
Check the content of the output message and reconfirm that there are no problems with the connection to HULFT.
E110023
- Description:
-
Terminating Agent because the management session was disconnected. Restart Agent.
- Measure:
-
Check the network environment to see if there are any problems with the connection to the HULFT-WebConnect service and then restart the sending-side Agent.
E110024
- Description:
-
Failed to terminate the sending-side Agent.
- Measure:
-
Use the Agent status confirmation command to check the status and then terminate the sending-side Agent again.
E110026
- Description:
-
An error occurred in the service. Code:[{0}], {1}
- Measure:
-
Check the network environment to see if there are any problems with the connection to the HULFT-WebConnect service.
E110029
- Description:
-
Unable to transfer the file because the total amount of the data transferred in this month exceeded the limit of the Trial version. Details:[{0}], {1}
- Measure:
-
If the expiration date of the Trial version license is next month or after, transfer the file again next month or after. If the expiration date is within the current month, purchase and apply the Product version license.
E110030
- Description:
-
Unable to transfer the file because the license of the receiving side cannot be checked. ReceivingHost:[{0}], {1}
- Measure:
-
The license on the receiving side has expired or is in violation of its terms. Register a valid Product version license.
E110031
- Description:
-
Unable to issue a request because the license of the request acknowledge side cannot be checked. {0}, RemoteHost:[{1}]
- Measure:
-
The license on the request acknowledge side has expired or is in violation of its terms. Register a valid Product version license.
E110034
- Description:
-
Failed in the send request processing The Connection ID is not specified in the message of the utlrecv command or the format is invalid. {0}, ServiceName:[{1}], RequestorHost:[{2}], RequestDestinationHost:[{3}]
- Measure:
-
Check whether the Connection ID is specified in the message of the utlrecv command. If the Connection ID is specified, check its format.
E110035
- Description:
-
Failed in the send request processing. Multiple Connection IDs are specified in the message of the utlrecv command. {0}, ServiceName:[{1}], RequestorHost:[{2}], RequestDestinationHost:[{3}]
- Measure:
-
Specify a single Connection ID in the message of the utlrecv command.
E110036
- Description:
-
Failed in the send request processing. The Connection ID specified in the message of the utlrecv command does not exist in the keystore file of Agent. {0}, ServiceName:[{1}], RequestorHost:[{2}], RequestDestinationHost:[{3}]
- Measure:
-
Check whether the Connection ID specified in the message of the utlrecv command is registered in the Connection ID authentication settings file.
E110037
- Description:
-
The service request processing was canceled. Unsupported service request cannot be relayed. {0}, ServiceName:[{1}], RequestorHost:[{2}], RequestDestinationHost:[{3}]
- Measure:
-
Perform a service request that supports HULFT-WebConnect.
E110038
- Description:
-
Failed in the resend request processing. The send request log does not exist. {0}, ServiceName:[{1}], RequestorHost:[{2}], RequestDestinationHost:[{3}]
- Measure:
-
Check whether a request acknowledge log record exists for the file ID specified in the parameter of the utlrecv command.
E110039
- Description:
-
Failed in the resend request processing. The file ID is not specified in the parameter of the utlrecv command. {0}, ServiceName:[{1}], RequestorHost:[{2}], RequestDestinationHost:[{3}]
- Measure:
-
Confirm that the file ID is specified in the parameter of the utlrecv command.
E110042
- Description:
-
The format of the host name is invalid. HostName:[{0}], {1}
- Measure:
-
Check the format of the host name that you specified when transferring the file.
E110046
- Description:
-
Unable to transfer the file because Agent is not running.
- Measure:
-
Use the Agent status confirmation command to check the status and then restart the sending-side Agent.
E110047
- Description:
-
The RMI server cannot be referred. Terminating the sending-side Agent.
- Measure:
-
Use the Agent status confirmation command to check the status and then restart the sending-side Agent.
E110049
- Description:
-
The connection from the sending-side Agent was not authenticated by the service. Confirm whether the Connection Settings are correct or not. {0}
- Measure:
-
Confirm that 'HULFT' is selected for Connectable Client Type in the Connection Settings on Management Console.
E110051
- Description:
-
The receiving-side Connection ID does not exist. {0}
- Measure:
-
Confirm that the Connection ID of the receiving side is registered in the Connection Settings on Management Console.
E110052
- Description:
-
An error occurred during the communication between the sending-side Agent and the service. {0}, Cause:[{1}], Message:[{2}]
- Measure:
-
Check the network environment to see if there are any problems with the connection to the HULFT-WebConnect service.
E110053
- Description:
-
The Trial version license is expired. [{0}], {1}
- Measure:
-
The Trial version license has expired. If you want to continue using HULFT-WebConnect, purchase and apply a Product version license.
E110055
- Description:
-
If the license is not registered, the service cannot be used. Register the license on the HULFT-WebConnect Management Console. [{0}], {1}
- Measure:
-
Your Product version license has expired or is in violation of its terms. Register a valid Product version license.
E110056
- Description:
-
The Connection ID authentication settings file contains the Connection ID that was registered with the different account. File: [{0}], {1}
- Measure:
-
Check the Connection ID that you registered in the Connection ID authentication settings file.
E110057
- Description:
-
The connection to the service was denied due to IP filter setting. {0}
- Measure:
-
Check the IP filter settings and then restart the sending-side Agent.
E119999
- Description:
-
Failed to start the sending-side Agent. [{0}]
- Measure:
-
Check the output message and then restart the sending-side Agent.
E120003
- Description:
-
The receiving-side Agent is already running.
- Measure:
-
Terminate the receiving-side Agent that is running and then restart the receiving-side Agent.
E120006
- Description:
-
The connection from the receiving-side Agent was not authenticated by the service. Confirm whether the contents of the Connection ID authentication settings file are correct or not. {0}
- Measure:
-
Check the Connection ID and the Connection Password that you registered in the Connection ID authentication settings file.
E120007
- Description:
-
Failed to connect to the service from the receiving-side Agent.
- Measure:
-
Check the network environment to see if there are any problems with the connection to the HULFT-WebConnect service. If connecting via the proxy server, check the fields under 'Proxy Information Settings' in the Agent configuration file.
E120010
- Description:
-
Failed to connect to HULFT. {0}, Host:[{1}], Port:[{2}]
- Measure:
-
Check the network environment to see if there are any problems with the connection to HULFT.
Also, confirm the following:
-
The Receive process or Receive daemon of HULFT on the receiving side has been started.
-
There are no errors in the settings of HULFT management information on the sending side.
-
E120011
- Description:
-
Authentication of the transfer session failed.
- Measure:
-
Check the network environment to see if there are any problems with the connection to the HULFT-WebConnect service. If connecting via the proxy server, check the fields under 'Proxy Information Settings' in the Agent configuration file.
E120016
- Description:
-
An error occurred during the communication with the receiving-side HULFT. {0}, Cause:[{1}], Message:[{2}]
- Measure:
-
Check the content of the output message and reconfirm that there are no problems with the connection to HULFT.
E120024
- Description:
-
Terminating Agent because the management session was disconnected. Restart Agent.
- Measure:
-
Check the network environment to see if there are any problems with the connection to the HULFT-WebConnect service and then restart the receiving-side Agent.
E120025
- Description:
-
Failed to terminate the receiving-side Agent.
- Measure:
-
Use the Agent status confirmation command to check the status and then terminate the receiving-side Agent again.
E120026
- Description:
-
Failed to establish the transfer session. Message:[{0}]
- Measure:
-
Check the network environment to see if there are any problems with the connection to the HULFT-WebConnect service. If connecting via the proxy server, check the fields under 'Proxy Information Settings' in the Agent configuration file.
E120034
- Description:
-
The RMI server cannot be referred. Terminating the receiving-side Agent.
- Measure:
-
Use the Agent status confirmation command to check the status and then restart the receiving-side Agent.
E120036
- Description:
-
The connection from the receiving-side Agent was not authenticated by the service. Confirm whether the Connection Settings are correct or not. {0}
- Measure:
-
Confirm that 'HULFT' is selected for Connectable Client Type in the Connection Settings on Management Console.
E120038
- Description:
-
An error occurred during the communication between the receiving-side Agent and the service. Cause:[{0}], Message:[{1}]
- Measure:
-
Check the network environment to see if there are any problems with the connection to the HULFT-WebConnect service.
E120039
- Description:
-
The Trial version license is expired. [{0}], {1}
- Measure:
-
The Trial version license has expired. If you want to continue using HULFT-WebConnect, purchase and apply a Product version license.
E120041
- Description:
-
If the license is not registered, the service cannot be used. Register the license on the HULFT-WebConnect Management Console. [{0}], {1}
- Measure:
-
Your Product version license has expired or is in violation of its terms. Register a valid Product version license.
E120042
- Description:
-
The Connection ID authentication settings file contains the Connection ID that was registered with the different account. File: [{0}], {1}
- Measure:
-
Check the Connection ID that you registered in the Connection ID authentication settings file.
E120043
- Description:
-
The connection to the service was denied due to IP filter setting. {0}
- Measure:
-
Check the IP filter settings and then restart the receiving-side Agent.
E120044
- Description:
-
Authentication of the transfer session failed. The session on the sending side was disconnected.
- Measure:
-
Check the network environment on the sending side to see if there are any problems with the connection to the HULFT-WebConnect service. Also, confirm that there are no connection problems with Agent and HULFT on the sending side.
E129999
- Description:
-
Failed to start the receiving-side Agent. [{0}]
- Measure:
-
Check the output message and then restart the receiving-side Agent.
E130009
- Description:
-
Failed to connect to the RMI server.
- Measure:
-
Use the Agent status confirmation command to check the status and then restart Agent.
E130010
- Description:
-
Connecting to the RMI server that is started on the different directory. Specify the port for internal communications again.
- Measure:
-
Check the value that you registered for 'agent.command.port' in the Agent configuration file.
E130011
- Description:
-
Failed to start the RMI server. [{0}]
- Measure:
-
Check the output message and then restart Agent.
E130012
- Description:
-
The port for internal communications is already in use by the other processes.
- Measure:
-
Check the value that you registered for 'agent.command.port' in the Agent configuration file and perform one of the following actions:
-
Register a port number that is not in use.
-
Assign a different port number to the other application or process that is using the port number.
-
E130013
- Description:
-
Failed to execute the command due to a communication error.
- Measure:
-
Use the Agent status confirmation command to check the status and then execute again the command that you executed.
E130014
- Description:
-
Agent that is running cannot be checked. Stopping the RMI server.
- Measure:
-
Use the Agent status confirmation command to check the status and then restart Agent.
E130015
- Description:
-
The command time-out occurred.
- Measure:
-
Check the network environment to see if there are any problems with the connection to the HULFT-WebConnect service and then restart Agent.
E140003
- Description:
-
Process startup settings on the sending and receiving sides are invalid. Modify the settings to start the process on the both sides or either side.
- Measure:
-
Specify 'on' for either or both of the following fields in the Agent configuration file:
-
windows.service.startup.sender
-
windows.service.startup.receiver
-
E140005
- Description:
-
The Windows service was not started successfully.
- Measure:
-
Use the Agent status confirmation command to check the status and then restart Agent by restarting the service or by using the Agent startup command.
E140008
- Description:
-
The Windows service cannot be terminated because there is a process which does not acknowledge the termination request.
- Measure:
-
Use the Agent status confirmation command to check the status and then terminate Agent again by terminating the service again or by using the Agent termination command.
E140009
- Description:
-
The Windows service was not terminated successfully.
- Measure:
-
Use the Agent status confirmation command to check the status and then terminate Agent again by terminating the service again or by using the Agent termination command.
E140010
- Description:
-
The Agent is already running.
- Measure:
-
Terminate the Agent that is running and then restart the Windows service.
E600003
- Description:
-
Failed to read the configuration file. File:[{0}], Message:[{1}]
- Measure:
-
Check if the Agent configuration file exists in the following path:
-
{Agent installation directory}/config/agent.conf
-
E600004
- Description:
-
The configuration file is invalid. Message:[{0}]
- Measure:
-
Check the content that you registered in the Agent configuration file.
E600013
- Description:
-
Failed to check for updates. Message:[{0}]
- Measure 1:
-
Register the following value for 'service.accesspoint' in the Agent configuration file:
-
service-ap.tokyo.webconnect.hulft.com
-
- Measure 2:
-
Check the network environment to see if there are any problems with the connection to the HULFT-WebConnect service. If connecting via the proxy server, check the fields under 'Proxy Information Settings' in the Agent configuration file.
E600027
- Description:
-
Failed to execute the application. Message:[{0}]
- Measure:
-
Check the content of the output message and then execute again the command that you executed.
E600028
- Description:
-
The update is already running by the other processes.
- Measure:
-
Once the update that is running is complete, update Agent again.