HIOT-108
Next Scheduled Sync Time might show the later time than the intended schedule.
- Phenomenon
-
For the Agent operation settings, if the user sets Polling Interval between 30 seconds and 59 seconds, Next Scheduled Sync Time shows the time that is one minute later than the intended time.
Also, if the user sets Polling Interval between 30 minutes and 59 minutes, Next Scheduled Sync Time shows the time that is one hour later than the intended time.
- Affected versions
-
From Ver.1.0.0 to Ver.1.5.0
- Version when it was corrected
-
Ver.2.0.0
- Affected module
-
HULFT IoT Manager
- Condition to reproduce
-
The phenomenon occurred when the user set Polling Interval between 30 seconds and 59 seconds or between 30 minutes and 59 minutes.
- Alternative workaround
-
None
- Status description
-
Next Scheduled Sync Time shows a correct schedule.