When a script is executed using the 32-bit Runtime module, where a value of 2147483648 or greater is specified for "Zero Padding" in mapping, an error occurs
- Phenomenon
-
When a script is executed using the 32-bit Runtime module, where a value of 2147483648 or greater is specified for "Zero Padding" in mapping, a Runtime error occurs.
- Affected versions
-
Ver.2.0.0
- Corrected version
-
Ver.2.1.0
- Affected module
-
HULFT IoT EdgeStreaming Runtime
- Condition to reproduce
-
The phenomenon occurs when the 32-bit Runtime module is used to execute the following procedure:
-
Place the mapping icon onto the script canvas.
-
Open the mapping icon. Then, on the mapping screen, place Zero Padding onto the mapping canvas.
-
On the Zero Padding Logic Properties screen, enter a value of "2147483648" or greater in "Size".
-
Click [Finish] to save the value.
-
Execute the script by using the 32-bit Runtime module.
-
- Alternative workaround
-
None
- Status description
-
Even when the 32-bit module is used, Runtime operates successfully.