ES-1242
HULFT IoT EdgeStreaming Studio may hang when you stop a remote device execution from HULFT IoT EdgeStreaming Studio
- Phenomenon
-
HULFT IoT EdgeStreaming Studio may hang when you stop a remote device execution from HULFT IoT EdgeStreaming Studio.
If this phenomenon occurs, terminate all the following processes of HULFT IoT EdgeStreaming Studio from the Task Manager:
-
-
EdgeStreaming.exe
-
esserver.exe
-
esstudio.exe
-
- Affected versions
-
From Ver.2.1.0 to Ver.2.2.0
- Corrected version
-
Ver.2.3.0
- Affected module
-
HULFT IoT EdgeStreaming Studio
- Condition to reproduce
-
This phenomenon occurs when you follow the procedure below:
-
Perform a remote device execution for an environment where inbound http requests to the port number "15601" are not allowed.
-
Stop the above remote device execution from HULFT IoT EdgeStreaming Studio.
-
- Alternative workaround
-
Allow inbound http requests to the port number "15601" on the remote device.
- Status description
-
When you perform a remote device execution for an environment where inbound http requests to the port number "15601" are not allowed and then stop the execution from HULFT IoT EdgeStreaming Studio, an error dialog box is displayed after a while and the script that is executed in the remote device ends.