HULFT IoT EdgeStreaming Studio may hang when you stop a remote device execution from HULFT IoT EdgeStreaming Studio

Phenomenon

HULFT IoT EdgeStreaming Studio may hang when you stop a remote device execution from HULFT IoT EdgeStreaming Studio.

If this phenomenon occurs, terminate all the following processes of HULFT IoT EdgeStreaming Studio from the Task Manager:

  • EdgeStreaming.exe

  • esserver.exe

  • esstudio.exe

Affected versions

From Ver.2.1.0 to Ver.2.2.0

Corrected version

Ver.2.3.0

Affected module

HULFT IoT EdgeStreaming Studio

Condition to reproduce

This phenomenon occurs when you follow the procedure below:

  1. Perform a remote device execution for an environment where inbound http requests to the port number "15601" are not allowed.

  2. Stop the above remote device execution from HULFT IoT EdgeStreaming Studio.

Alternative workaround

Allow inbound http requests to the port number "15601" on the remote device.

Status description

When you perform a remote device execution for an environment where inbound http requests to the port number "15601" are not allowed and then stop the execution from HULFT IoT EdgeStreaming Studio, an error dialog box is displayed after a while and the script that is executed in the remote device ends.