Improved features

For details on each improved feature, see the relevant topic from the link of the management number below.

HULFT IoT Manager and HULFT IoT Agent

Management number

Brief description

Version when it was improved

HIOT-552

Multi-byte characters are available for "Monitored file name" and "File name at send destination"

2.2.0

HIOT-92

Usage of HULFT IoT in the environment using an SSL accelerator

2.0.0

HULFT IoT Manager

Management number

Brief description

Version when it was improved

HIOT-732

Fixed the vulnerability (CVE-2022-21476)

2.3.2

HIOT-221

The initial settings for the log truncation function are improved

2.3.2

HIOT-296

Manager operation improvement when the number of tasks in the Receive Task Queue is maximum

2.0.0

HIOT-732

Fixed the vulnerability (CVE-2022-21476)

1.5.1

HIPJ-1367

Parameters that are unnecessary or do not return any value are deleted from the REST API

1.5.0

HIPJ-1354

Installer options of HULFT IoT Manager for Linux are changed

1.5.0

HIPJ-1321

Usage that is displayed by the installer of HULFT IoT Manager for Linux is improved

1.5.0

HIPJ-1319

The installer screen is improved

1.5.0

HIPJ-1318

Log messages are improved

1.5.0

HIPJ-1312

JRE 8 is removed from the necessary software

1.5.0

HIPJ-1311

The installation module of HULFT IoT Manager for Windows is changed to ZIP format

1.5.0

HIPJ-1308

The directory structure of the product media is revised

1.5.0

HIPJ-1153

API response parameters are added

1.4.1

HIPJ-1137

Deletion of unnecessary parameters

1.4.1

HIPJ-512

Specification improvement for installation

1.4.1

HIPJ-703

Change of a search condition on Unit List screen from complete match to partial match

1.4.0

HIPJ-652

End of Java installation path restrictions for Manager in Linux environment

1.4.0

HIPJ-628

The term of API function is specified by seconds, but not by milliseconds

1.4.0

HIPJ-475

Deletion of a setting of Transfer Encoding from Profile

1.4.0

HIPJ-434

Change of a method to specify a Manager home directory

1.4.0

HIPJ-487

Log message is improved

1.3.1

HULFT IoT Agent

Management number

Brief description

Version when it was improved

HIOT-306

Dividing the output directory for the Agent system files and the temporary storage directory for the log files

2.0.0

HIPJ-1426

Windows service name of HULFT IoT Agent for Windows is variable

1.5.0

HIPJ-1253

The user experience for introduction is improved

1.5.0

HIPJ-447

Specification of an IPV4 address

1.4.0

HULFT IoT EdgeStreaming

Management number

Brief description

Version when it was improved

ES-1586

Fixed the vulnerability (CVE-2022-21476)

2.3.2

ES-1360

License check was improved

2.3.2

ES-1182

The field names displayed in the mapping properties were changed

2.3.0

ES-1181

The field name displayed on the Stream setting tab was changed

2.3.0

ES-1099

"Timestamp" is displayed in the execution log that is output in HULFT IoT EdgeStreaming Studio

2.3.0

ES-1048

Icons for "Parse of date/time" and "Date/Time formatting" are improved

2.3.0

ES-997

The title of the "Build" screen is changed to "Build and deploy script to local folder"

2.3.0

ES-989

The tooltip of the icon is changed to "Build and deploy script to local folder"

2.3.0

ES-914

The name of the standard output adapter is output to the execution log

2.3.0

ES-790

Maximum values for some logics of mapping were changed to improve performance

2.2.0

ES-745

The notation and placement of the menu items of Designer are revised

2.2.0

ES-506

Operation of "Open explorer" and "Open terminal" in the right-click menu of a script was improved

2.2.0

ES-438

Operation when internal buffer utilization of EdgeStreaming Runtime reaches the upper limit was improved

2.2.0

ES-400

Operation when EdgeStreaming Runtime has a startup error during testing was improved

2.2.0

ES-391

USB adapter supports the BackSpace key

2.2.0

ES-276

Acquisition of the local time of the operating environment for EdgeStreaming Runtime

2.2.0

ES-272

Function was improved so that a schema defined by the CSV adapter can be read from the first line of a CSV file

2.2.0

ES-250

[Column name] of "Schema definition" for RDB adapters was improved to be input only automatically

2.2.0

ES-197

The range of Slave ID numbers that can be specified through the Modbus adapter

2.1.0

ES-51

Operation when a connection destination is stopped was improved

2.1.0

ES-33

A portion of the search conditions of My Projects were deleted

2.1.0

ES-32

The field related to the "User management" feature was deleted

2.1.0

ES-10

A menu name was changed

2.1.0

ES-6

The fields related to the "File owner" and "Shared project" features were deleted

2.1.0

ES-5

"Data flow" was unified as "Stream flow"

2.1.0