HIPJ-520
When "job_exec_module" is specified in the settings file (lockdown.conf), the parameters that are used for starting a user command are not divided by spaces
- Phenomenon
-
When you prescribe the Agent actions by specifying the settings file (lockdown.conf), if you prescribe the job execution mode by specifying "job_exec_module", specified parameters are not divided by spaces when they are given to an execution module.
- Affected versions
-
Ver.1.3.0
- Version when it was corrected
-
Ver.1.3.1
- Affected module
-
HULFT IoT Agent
- Condition to reproduce
-
This phenomenon occurs when all the following conditions are met:
-
After specifying "job_exec_module" in the settings file (lockdown.conf), Agent starts.
-
Multiple parameters are set when a job for transfer settings or reception settings is registered on the operation screen of Manager.
-
- Alternative workaround
-
None
- Status description
Parameters that are separated by spaces are given to the execution module.