Official | HULFT IoT Release Note Fourth Edition: July 1, 2021
HIPJ-96
A monitored file may be detected repeatedly
- Phenomenon
-
Agent may repeatedly detect a monitored file. If the monitored file is detected repeatedly, one transfer will succeed, but the other transfer will fail as a following error:
- Affected versions
-
From Ver.1.0.0 to Ver.1.3.1
- Version when it was corrected
-
Ver.1.4.0
- Affected module
-
HULFT IoT Agent
- Condition to reproduce
-
This phenomenon might occur when all the following conditions are met:
-
"Delete" is registered for the "File Deletion after Transfer" of the transfer settings by using an operation screen of Manager.
-
The file is monitored with a high frequency.
-
- Alternative workaround
-
The occurrence of this issue will reduce by reducing the frequency of the file monitoring.
- Status description
-
Even if the conditions described at the condition to reproduce are met, a monitored file will not be detected repeatedly.
Error code: 1001
Content: File open failed.