Official | HULFT IoT Release Note Fourth Edition: July 1, 2021

HIPJ-808

If an auto resend retry is repeated more than 255 times, you may not refer or delete the receive logs correctly on the management screen of HULFT

Phenomenon

If the auto resend retry operation is executed more than 255 times, the identifier for each transfer is duplicated so that the log cannot be assigned to the transfer. Therefore, the reference or deletion of the receive logs on the management screen of HULFT does not correctly processed.

Affected versions

From Ver.1.0.0 to Ver.1.3.1

Version when it was corrected

Ver.1.4.0

Affected module

HULFT IoT Manager

Condition to reproduce

This phenomenon occurs when all the following conditions are met:

  • File transfer that was executed by a setting of "Auto resend retry" was repeated more than 255 times.

  • The receive log that was output when the file transfer was executed by a setting of "Auto resend retry" for the 256th or more time is referred or deleted.

Alternative workaround

None

Status description

The maximum number for the auto resend retry count changed to 255 times. And even if the conditions described at the condition to reproduce are met, you can correctly refer and delete the receive log.

For details, see the section of compatibility loss occurred at version 1.4.0.

 

 

Official | HULFT IoT Release Note Fourth Edition: July 1, 2021