HIPJ-518
When "job_exec_module" is specified in the settings file (lockdown.conf), Agent might not transfer or receive files
- Phenomenon
-
When you prescribe the Agent actions by specifying the settings file (lockdown.conf), if you prescribe the operation of the job execution by specifying "job_exec_module", Agent might not transfer or receive files.
- Affected versions
-
Ver.1.3.0
- Version when it was corrected
-
Ver.1.3.1
- Affected module
-
HULFT IoT Agent
- Condition to reproduce
-
This phenomenon occurs when all the following conditions are met:
After specifying "job_exec_module" in the settings file (lockdown.conf), Agent starts.
Transfer settings or reception settings are registered without specifying a job (default) on the operation screen of Manager.
- Alternative workaround
-
If you prescribed "job_exec_module" in the settings file (lockdown.conf), specify "Step Execution" to the job execution mode for transfer settings or reception settings.
- Status description
-
Even if "Script Execution" is set to the job execution mode for transfer settings or reception settings, when the job is not specified, the triggers are normally fired or the receptions are normally executed.