HIPJ-1273
HULFT IoT Agent might execute a send processing of log information to HULFT IoT Manager every second
- Phenomenon
-
By some reason such as a malfunction occurs on the network or the polling interval is too long, the transfer logs or trace logs are accumulated on the HULFT IoT Agent environment separately ( _agentsnd.log.sequential# files and _agenttrace.log.sequential# files are created in the HULFT IoT Agent environment).
In this case, when HULFT IoT Agent connects HULFT IoT Manager, HULFT IoT Agent might execute a send processing of the log information to HULFT IoT Manager every second but not at polling intervals.
- Affected versions
-
From Ver.1.4.0 to Ver.1.4.1
- Version when it was corrected
-
Ver.1.5.0
- Affected module
-
HULFT IoT Agent
- Condition to reproduce
-
This phenomenon occurs after HULFT IoT Agent connects HULFT IoT Manager during all of the following conditions are met:
-
Log information has been divided by some reason such as network malfunction or a long polling interval, and the _agentsnd.log.sequential# files and the _agenttrace.log.sequential# files exist in the HULFT IoT Agent environment.
-
HULFT IoT Agent is performing with the "communication time limit" setting to "off".
-
- Alternative workaround
-
None
- Status description
-
When the conditions described at the condition to reproduce are met, even after HULFT IoT Agent connected HULFT IoT Manager, HULFT IoT Agent sends the log information at polling intervals.