Official | HULFT IoT Release Note Fourth Edition: July 1, 2021

HIPJ-1148

If the characters that are longer than the specifiable length are written in a successful job or an unsuccessful job by using the "Modify Transfer Settings details" API function, the returned HTTP status code is not appropriate

Phenomenon

If the characters that are longer than the specifiable length are written in a successful job or an unsuccessful job by using the "Modify Transfer Settings details" API function, the returned HTTP status code is "500" that is not appropriate.

Affected versions

Ver.1.4.0

Version when it was corrected

Ver.1.4.1

Affected module

HULFT IoT Manager

Condition to reproduce

This phenomenon occurs when the characters that are longer than the specifiable length are written in a successful job or an unsuccessful job by using the "Modify Transfer Settings details" API function.

Alternative workaround

None

Status description

If the characters exceeding the specifiable length are specified, HTTP status code "400" is returned.

 

 