ES-236
Double-byte characters are inadvertently entered in the value input fields for a portion of the adapters
- Phenomenon
-
Double-byte characters are inadvertently entered in the value input fields for a portion of the adapters.
If a double-byte character is entered when the script is executed, an error occurs in HULFT IoT Runtime and cannot start.
- Affected versions
-
Ver.2.0.0
- Corrected version
-
Ver.2.1.0
- Affected module
-
HULFT IoT EdgeStreaming Runtime
- Condition to reproduce
-
The phenomenon occurs when the following procedure is executed:
-
Place any of the following adapters onto the script canvas.
-
Basic adapter: Basic - Monitoring - Acquire OS Resources
-
File adapter: File - Basic - Write
-
Modbus adapter: Industrial-use device - Modbus - Read Coils
-
Modbus adapter: Industrial-use device - Modbus - Read Input Status
-
Modbus adapter: Industrial-use device - Modbus - Read Input Register
-
Modbus adapter: Industrial-use device - Modbus - Read Holding Registers
-
Modbus adapter: Industrial-use device - Modbus - Write Single Coil
-
Modbus adapter: Industrial-use device - Modbus - Write Holding Registers
-
-
On the Properties screen of the adapter, enter a double-byte number into any of the value input fields.
-
Click [Finish] to save the value.
-
- Alternative workaround
-
None
- Status description
-
Double-byte characters cannot be saved in the value input fields of any of the adapters.