Receive processing (SAN) messages
- XRRSN01
-
HULFT-SAN IS AVAILABLE
- Description:
-
HULFT-SAN is installed. (ML=I)
- XRRHR01
-
SAN RECEIVE IS INITIATED
- Description:
-
The Receive processing started in HULFT-SAN. (ML=I)
- XRRHR03
-
CHANGED LAN RECEIVE
- Description:
-
The data is transferred via LAN, because the conditions for transfer via HULFT-SAN were not met. (ML=W)
- XRRHR04
-
INVALID RECEIVE FILE FOR SAN
- Description:
-
This file cannot be received in HULFT-SAN. (ML=W)
- Measures:
-
Check the Receive file.
- XRRHR05
-
MULTI VOLUME IS NOT SPECIFIED FOR SAN(FAL) TRANSFER
- Description:
-
Multi is specified for the Multivolume in the Receive Management Information. (ML=W)
- XRRHR06
-
GDG IS NOT SPECIFIED FOR SAN(FAL) TRANSFER
- Description:
-
Generation Management is specified for the Catalog Operation in the Receive Management Information. (ML=W)
- XRRHR07
-
MODIFY IS NOT SPECIFIED FOR SAN(FAL) TRANSFER
- Description:
-
Append is specified for the Registration Mode in the Receive Management Information. (ML=W)
- XRRHR08
-
MULTIPLE HOST IS NOT SPECIFIED FOR SAN(FAL) TRANSFER
- Description:
-
Multiple Receive is specified for the Receive Mode in the Receive Management Information. (ML=W)
- XRRHR09
-
ANSI OR MACHINE IS NOT SPECIFIED FOR SAN(FAL) TRANSFER
- Description:
-
ANSI or Machine is specified for the Print Character in the Receive Management Information. (ML=W)
- XRRHR10
-
MT IS NOT SPECIFIED FOR SAN(FAL) TRANSFER
- Description:
-
The type of the unit that is specified for the UNIT in the Receive Management Information is tape media (MT). (ML=W)
- XRRHR11
-
HULFT-SAN TRANSFER IS NOT INSTALLED
- Description:
-
HULFT-SAN is not installed on the host on the sending side. (ML=W)
- XRRHR12
-
SEND SIDE CANNOT SAN(FAL) TRANSFER
- Description:
-
The environment or conditions are not appropriate for SAN transfer. (ML=W)
- Measures:
-
Check the environments on the host on the sending side and the host on the receiving side. SAN transfer is not possible between Mainframes; therefore, make sure that the host on the sending side is not a Mainframe.
- XRRHR13
-
SMS-CLASS IS NOT SPECIFIED FOR SAN(FAL) TRANSFER
- Description:
-
The Storage Class, the Management Class, or the Data Class is specified for the Receive Management Information. (ML=W)
- XRRFS03
-
CHANGED LAN RECEIVE
- Description:
-
The data is transferred via LAN, because the conditions for transfer via HULFT-SAN were not met. (ML=W)
- XRRFS04
-
INSUFFICIENT MEMORY FOR XL-D MAP
- Description:
-
Failed to allocate the buffer for XL Data Mover link. (ML=E)
- Measures:
-
Increase the region size, and then rerun the Send program (XRSND).
- XRRFS05
-
INSUFFICIENT MEMORY FOR XL-D I/O
- Description:
-
Failed to allocate the buffer for XL Data Mover link. (ML=E)
- Measures:
-
Increase the region size, and then rerun the Send program (XRSND).
- XRRFS06
-
macro FAILED HST=Host Name FILEID=File ID RC=rccd-errcd
- macro:
-
XL Data Mover processing name
- rccd:
-
XL Data Mover recovery code
- errcd:
-
XL Data Mover detail code
- Description:
-
Failed to access the volume for data transfer of XL Data Mover. (ML=E)
- Measures:
-
Refer to the XL Data Mover handbook with the recovery code or detail code, and take the appropriate measures.
- XRRFS07
-
KJUOPEN ERR-INF=errcd1-errcd2
- errcd1:
-
XL Data Mover detail code 1
- errcd2:
-
XL Data Mover detail code 2
- Description:
-
An error has occurred during the attempt to open the volume for data transfer. (ML=E)
- Measures:
-
Refer to the XL Data Mover handbook with the detail code, and take the appropriate measures.
- XRRFS08
-
SAN RECEIVE IS INITIATED
- Description:
-