Execution of Post-send Job and Post-receive Job messages
- XRJ0001
-
JOB INF OPEN ERROR RC=fdbk FILEID=fileid
- fdbk:
-
Detail code for VSAM macro (FDBK)
- fileid:
-
File ID
- Description:
-
Failed to open the Send and Receive Management file. (ML=E)
- Measures:
-
A failure has occurred in the Send and Receive Management file (HULFT.FILE). Refer to the detail code for VSAM and take the appropriate measures.
- XRJ0002
-
JOB ID NOT EXIST JOBID=jobid
- jobid:
-
Job ID
- Description:
-
The Job ID does not exist in the Job Information. (ML=E)
- Measures:
-
Register the Job Information for the appropriate job ID.
- XRJ0003
-
JCL LIBRARY ALLOC ERROR RC=code FILEID=fileid
- code:
-
Error code for DYNALLOC macro
- fileid:
-
File ID
- Description:
-
Failed to allocate the JCL library. (ML=E)
- Measures:
-
The JCL library may not exist, or there could be another cause. Refer to the DYNALLOC macro error codes, and take the appropriate measures.
- XRJ0004
-
JCL LIBRARY OPEN FAILED FILEID=fileid
- fileid:
-
File ID
- Description:
-
Failed to open the JCL library. (ML=E)
- Measures:
-
The file organization attribute of the JCL library may not be Partitioned Organization, or there could be another cause. Check the JCL library.
- XRJ0005
-
JCL MEMBER IS NOT EXIST FILEID=fileid JOBID=jobid
- fileid:
-
File ID
- jobid:
-
Job ID
- Description:
-
The startup job that is registered in the Job Information does not exist. (ML=E)
- Measures:
-
Register the startup job in the Job Information again, or create the startup job.
- XRJ0006
-
JCL MEMBER READ ERROR
- Description:
-
Failed to read the startup job. (ML=E)
- Measures:
-
There may have been an error in the JCL library. Check the JCL library.
- XRJ0007
-
JCL LIBRARY CLOSE FAILED
- Description:
-
Failed to close the JCL library. (ML=E)
- Measures:
-
There may have been an error in the JCL library. Check the JCL library.
- XRJ0008
-
JCL LIBRARY FREE ERROR RC=code
- code:
-
Error code for DYNALLOC macro
- Description:
-
Failed to release the JCL library. (ML=E)
- Measures:
-
Refer to the DYNALLOC macro error codes, and take the appropriate measures.
- XRJ0009
-
INTRDR ALLOCATION ERROR RC=code FILEID=fileid
- code:
-
Error code for DYNALLOC macro
- fileid:
-
File ID
- Description:
-
Failed to allocate the internal reader. (ML=E)
- Measures:
-
This is HULFT system error. Contact your Technical Support Service representative, if you have already concluded the Technical Support Agreement.
- XRJ0010
-
INIRDR OPEN FAILED
- Description:
-
Failed to open the internal reader. (ML=E)
- Measures:
-
This is HULFT system error. Contact your Technical Support Service representative, if you have already concluded the Technical Support Agreement.
- XRJ0011
-
INTRDR CLOSE FAILED
- Description:
-
Failed to close the internal reader. (ML=E)
- Measures:
-
This is HULFT system error. Contact your Technical Support Service representative, if you have already concluded the Technical Support Agreement.
- XRJ0012
-
INTRDR FREE ERROR RC=code
- code:
-
Error code for DYNALLOC macro
- Description:
-
Failed to release the internal reader. (ML=E)
- Measures:
-
This is HULFT system error. Contact your Technical Support Service representative, if you have already concluded the Technical Support Agreement.
- XRJ0013
-
RECEIVE INF GET ERROR
- Description:
-
Failed to read the applicable Receive Management Information records. (ML=E)
- Measures:
-
The applicable Receive Management Information records may have been deleted. Register the applicable information records.
- XRJ0014
-
JOB EXECUTION COMPLETE JOBID=jobid
- jobid:
-
Job ID
- Description:
-
Execution of the job was completed successfully. (ML=I)
- XRJ0020
-
INTRDR ALLOC RETRY
- Description:
-
Could not use the internal reader. Try executing the procedure once again. (ML=W)
- XRJ0021
-
MSGX CONVERSION ERROR FILEID=fileid
- fileid:
-
File ID
- Description:
-
Unable to replace the name of the JCL library that is registered in the Job Information with the specified message. (ML=E)
- Measures:
-
Register the startup job in the Job Information again, or check the MSG of the Send File.
- XRJ8005
-
JCL MEMBER NOT EXIST JOBID=jobid
FILEID=fileid
- jobid:
-
Job ID
- fileid:
-
File ID
- Description:
-
The startup job that is registered in the Job Information does not exist. (ML=E)
- Measures:
-
Register the startup job in the Job Information again, or create the start job.