Send Request command (utlrecv.exe)
1
- Description:
-
The parameter specification is invalid.
- Measure:
-
Check whether the entered parameter is correct.
2
- Description:
-
Acquisition of the host name failed.
- Measure:
-
Check network settings.
3
- Description:
-
Failed to receive data.
- Measure:
-
Check the communication environment.
4
- Description 1:
-
The Receive Management Information has not been registered.
- Description 2:
-
The transfer group ID specified in the Receive Management Information has not been registered in the Transfer Group Information.
- Description 3:
-
The host name registered with the transfer group ID specified in the Receive Management Information has not been registered in the Host Information.
- Measure 1:
-
Register the file ID specified with the parameter in the Receive Management Information.
- Measure 2:
-
Register the transfer group ID specified for the Receive Management Information in the Transfer Group Information.
- Measure 3:
-
In the Host Information, register the host name registered with the transfer group ID specified in the Receive Management Information.
5
- Description:
-
Reading management information failed.
- Measure:
-
Check access permissions of the Management Information.
6
- Description:
-
Transfer Group ID in the Receive Management Information has not been specified.
- Measure 1:
-
Specify Transfer Group ID in the Receive Management Information.
- Measure 2:
-
Specify a host name with the '-h' parameter.
7
- Description:
-
Insufficient memory.
- Measure:
-
Terminate any unnecessary applications.
10
- Description:
-
Creation of a thread failed.
- Measure:
-
System resource is insufficient. Exit unnecessary applications.
11
- Description:
-
Socket connection failed.
- Measure 1:
-
Check whether the Observe process has been started on the remote host.
- Measure 2:
-
Set a large value to Connect Retry Count (retrycnt) and Connect Retry Interval (retrytime).
- Measure 3:
-
To acknowledge the request from the remote host, increase Connect Retry Count (retrycnt) in the System Environment Settings file (hulenv.cnf).
12
- Description:
-
A communication error occurred.
- Measure:
-
Check network settings.
13
- Description:
-
Data receive failed.
- Measure:
-
Check the communication environment.
14
- Description:
-
The request was canceled by the request destination host.
- Measure:
-
Refer to the Observe Log of the request destination host.
15
- Description:
-
An error occurred at the request destination host.
- Measure:
-
Check the Observe Log file of the request destination host and take appropriate measure.
If you are using HULFT-HUB, check the Log of HULFT-HUB.
16
- Description:
-
an application error occurred.
- Measure:
-
Retry the Request operation.
17
- Description:
-
During a Synchronous Transfer, the transfer becomes abnormal at all hosts.
- Measure:
-
Check management information settings for all hosts and retry the Request operation.
18
- Description:
-
An error has occurred on one or more hosts during a Synchronous Transfer.
- Measure:
-
Check the host or hosts where the error occurred, and after applying the appropriate measures, retry the Request operation.
19
- Description:
-
Failed to receive data.
- Measure:
-
Check the communication environment.
21
- Description:
-
An error occurred on the proxy server.
- Measure:
-
Check the log file of the proxy server. After taking appropriate measures, retry issuing the request.
If you are using HULFT-HUB, check the log of HULFT-HUB.
22
- Description:
-
The value of Connection Type in the Host Information is invalid.
- Measure:
-
Check the value of Connection Type in the Host Information.
23
- Description:
-
Failed to acquire operating system information.
- Measure:
-
Check the environment as there may be an operating system error.
25
- Description:
-
During a Synchronous Transfer, all transfers were canceled.
26
- Description:
-
During a Synchronous Transfer, part of the transfer was canceled.
27
- Description:
-
Acquiring of IP address failed.
- Measure:
-
Register the host name in the hosts file or the DNS server.
31
- Description:
-
A version error occurred among HULFT of the host at the connection destination.
- Measure 1:
-
Unable to connect HULFT Firewall.
- Measure 2:
-
Unable to connect HULFT-HUB Server lower than Ver.2.2.
32 Failed to acquire HULFT Operation Language.
- Description:
-
Failed to acquire HULFT Operation Language.
- Measure:
-
Check the setting of HULFT Operation Language in the System Environment Settings.
33 A communication version error occurred. Specified file ID is unavailable. File ID=%s, Host Name=%s
- Description:
-
A communication version error occurred.
- Measure:
-
Check that the specified file ID is within 8 bytes.
34 Failed to acquire the System Environment Settings file.
- Description:
-
Reading the System Environment Settings file (hulenv.cnf) failed.
- Measure 1:
-
Check that the System Environment Settings file (hulenv.cnf) exists.
- Measure 2:
-
Check the access permissions for the System Environment Settings file (hulenv.cnf).
35 Failed to communicate in the Forced Strong Key mode. File ID=%s, Host Name=%s
- Description:
-
Failed to communicate in the Forced Strong Key mode.
- Measure:
-
Check that all of the following conditions are met on the destination host:
-
Forced Strong Key mode is enabled
-
HULFT Ver.8.4.0 or higher is installed
-
HULFT8 Cipher Option(AES) is installed
-
153 Error occurred during character code conversion.
- Description:
-
An error occurred during character code conversion.
- Measure:
-
Insufficient memory.
Terminate any unnecessary applications.
156 Failed to open the Command Message file of the command that you ran.
- Description:
-
Failed to open the Command Message file of the command that you ran.
- Measure 1:
-
Check that the file exists.
- Measure 2:
-
Check the access permissions for the file.