Explanation of each field
This section describes each field in the Installation Information file.
- SERIAL
-
Specify the Serial Number of the product in numeral of 13 bytes without hyphens.
= Remarks =Specification with hyphens is also possible in the following format of 15 bytes: NNN-NNNN-NNNNNN
- PRODUCTKEY
-
Specify the Product Key obtained from following website, in an alphanumeric character string of 25 bytes without hyphens:
http://www.hulft.com/= Remarks =Specification with hyphens is also possible in the following format of 29 bytes:
NNNNN-NNNNN-NNNNN-NNNNN-NNNNN - TERMLICENSEKEY
-
Specify the Term License Key in an alphanumeric character string within 25 bytes.
= Remarks =Specification with hyphens is also possible in the following format of 29 bytes:
NNNNN-NNNNN-NNNNN-NNNNN-NNNNN - INSTALLATIONROUTE
-
Specify one of the following installation routes:
- EXPRESS:
-
Express Installation
- CUSTOM:
-
Custom Installation
- HULPATH
-
Specify the HULFT environment settings file storage directory in an absolute path within 200 bytes.
- HULEXEP
-
Specify the HULFT execution module storage directory in an absolute path within 200 bytes.
- CS4TRNSFR
-
Specify the code set that HULFT uses for file transfers.
- EUC-JP:
-
EUC-JP
- SJIS:
-
Shift-JIS
- UTF-8:
-
UTF-8
- GB18030:
-
GB18030
Note-
HULFT uses the code set that you specify here as the default value of Code Set for Transfer (cs4trnsfr) in the System Environment Settings.
-
Specify a code set here that corresponds to the system locale.
-
If you specify 'GB18030,' English is used as the language for the following:
-
Content of the installation log
-
Comments in the System Environment Settings file
-
- HULLANG
-
Specify one of the following HULFT Operation Languages.
- JPN:
-
Japanese
- ENG:
-
English
This field is mandatory for New Installation. This field is optional for Update Installation.
If you omit this field, the setting value of the existing environment will be inherited.
Note-
HULFT uses the HULFT Operation Language that you specify here as the default value of HULFT Operation Language (hullang) in the System Environment Settings.
-
Specify the HULFT Operation Language here that corresponds to the system locale.
If the system locale is not Japanese, specify 'ENG' (English).
- INSTALLATIONTYPE
-
Specify the installation type. If you do not specify a value, "NEW" is used.
- NEW:
-
New Installation
- UPDATE:
-
Update Installation
- KEYUPDATE:
-
Product Key Update
- MYHOSTNAME
-
Specify the name of host on which you are going to install the application using Silent Installation, in an alphanumeric character string within 68 bytes.
This field is used only when you specify 'NEW' (New Installation) for INSTALLATIONTYPE. The setting of this field is disregarded when you select 'UPDATE' (Update Installation) or 'KEYUPDATE' (Product Key Update).
- TMPDIR
-
Specify the path to store temporary files in an absolute path within 200 bytes.
The directory that you specify for the path to store temporary files is used as the default value for the following field in the System Environment Settings:
-
Work File Generation Path
NoteWhen you run multiple instances of HULFT at the same time, specify the path to store temporary files for each instance of HULFT so that the path is different from the setting of Work File Generation Path for other instances of HULFT.
-
- DATEFMT
-
Specify one of the following date formats. If you do not specify a value, "1" is used. The setting of this field is disregarded for Update Installation.
- 1:
-
YYYY/MM/DD
- 2:
-
MM/DD/YYYY
- 3:
-
DD/MM/YYYY
- INSTALLNODE
-
Specify the installation node that you use with clustering functions. If you do not specify the value of this field, you cannot use clustering functions.
- Default:
-
Installation where you do not use clustering functions
- ACTIVE:
-
Installation as the ACTIVE node
- STANDBY:
-
Installation as the STANDBY node
- TRACEOUTPUTROUTE
-
Specify one of the following values for the output method of the trace log. If you do not specify a value, "N" is used.
- N:
-
Do not output
- T:
-
Output only to the trace output file
- S:
-
Output only to syslog
- B:
-
Output to both the trace output file and syslog
The value that you specify for this field is used as the setting values of Output to Trace Logs (tracelog) and Output to System Logs (syslog) in the System Environment Settings.
For details on each field of the System Environment Settings, refer to Administration Manual.
- PIDDIR
-
Specify the path to generate the pid file in an absolute path within 200 bytes. This field is mandatory when you specify 'ACTIVE' for INSTALLNODE. This field is not used in other cases.