Receive daemon

(1) Receive Start Time

Message (140 bytes per record (including line feed))

hulrcvd:  HOSTNAME=HP1 
FILEID=ID00001  DATE=2014/12/23  START TIME=13:22:00

HOSTNAME

Remote host name

68 alphanumeric characters (if less than 68 characters are used, the remaining digits are padded with space codes)

FILE ID

File ID

8 alphanumeric characters (if less than 8 characters are used, the remaining digits are padded with space codes)

DATE

Receive start date

START TIME

Receive start time

(2) Receive End Time

Message (171 bytes per record (including line feed))

hulrcvd:  HOSTNAME=HP1 
FILEID=ID00001  DATE=2014/12/23  START TIME=13:22:00 
END TIME=13:24:00  RC=0000-0000

HOSTNAME

Remote host name

68 alphanumeric characters (if less than 68 characters are used, the remaining digits are padded with space codes)

FILE ID

File ID

8 alphanumeric characters (if less than 8 characters are used, the remaining digits are padded with space codes)

DATE

Receive end date

START TIME

Receive start time

END TIME

Receive end time

RC

Status code

(3) CSV Interface Start Time

Message (86 bytes per record (including line feed))

hulrcvd : FILEID=FMT DBID=CSV MODE=REP
DATE=2014/12/23 START TIME=13:23:00

FILE ID

File ID

8 alphanumeric characters (if less than 8 characters are used, the remaining digits are padded with space codes)

DBID

Interface DBID

8 alphanumeric characters (if less than 8 characters are used, the remaining digits are padded with space codes)

MODE

Registration mode

NEW:

New Creation mode

REP:

Replace mode

MOD:

Append mode

DATE

Receive start date

START TIME

Interface processing start time

(4) CSV Interface End Time

Message (117 bytes per record (including line feed))

hulrcvd : FILEID=FMT      DBID=CSV      MODE=REP DATE=2014/12/23 START
TIME=13:23:00 END TIME=13:23:59 RC=0000-0000

FILE ID

File ID

8 alphanumeric characters (if less than 8 characters are used, the remaining digits are padded with space codes)

DBID

Interface DBID

8 alphanumeric characters (if less than 8 characters are used, the remaining digits are padded with space codes)

MODE

Registration mode

NEW:

New Creation mode

REP:

Replace mode

MOD:

Append mode

DATE

Receive start date

START TIME

Interface processing start time

END TIME

Interface processing end time

RC

Status code