Error codes for Multi Format Information

HUL2700

END NOT ENTER

Description:

END has not been entered in parameter file.

Measures:

Enter END in the end of each management information.

HUL2701

KEY MAX OVER

Description:

The number of keys exceeds the maximum number. (20)

Measures:

Set the number of keys to 20 or less.

HUL2702

KEY AND FMTID NOT ENTER

Description:

No format ID paired with a key value is registered.

Measures:

Register at least a format ID paired with a key value.

HUL2703

COMMENT TOO LONG

Description:

The Comment exceeds 60 bytes.

Measures:

Enter the comment in less than 60 characters.

HUL2704

BAD DATA TYPE

Description:

Specified tag name is incorrect.

Measures:

Enter the correct tag name.

HUL2705

KEY OR FMTID TOO LONG

Description:

Key value or format ID exceeds the maximum length.

Measures:

Shorten the key value to 20 bytes or less and format ID to 50 bytes or less, respectively.

HUL2706

DEFAULT FMTID TOO LONG

Description:

The default format ID exceeds the maximum length of 50 bytes.

Measures:

Shorten the default format ID to 50 bytes or less.

HUL2707

MFMT TOO LONG

Description:

The multi format ID exceeds the maximum length of 50 bytes.

Measures:

Shorten the multi format ID to 50 bytes or less.

HUL2708

NO INFORMATION MFMTID

Description:

Multi format ID has not been specified.

Measures:

Enter multi format ID.

HUL2709

KEY LENGTH ERROR

Description:

The lengths of the actual and specified keys are different.

Measures:

Specify a valid key or a valid key length.

HUL2710

NO INFORMATION KEY START POSITION OR BAD KEY START POSITION

Description:

No or an invalid key start position is specified.

Measures:

Specify a valid key start position. (1 to 19997)

HUL2711

NO INFORMATION KEY LENGTH OR BAD KEY LENGTH

Description:

No or an invalid key length is specified.

Measures:

Specify a valid key length. (1 to 20)

HUL2712

NO INFORMATION KEY OR FMT ID

Description:

No pair of the value for the format ID and the key value has been registered.

Measures:

Register at least one pair of values for the format ID and the key value.

HUL2713

KEY LENGTH OR KEY START POSITION ERROR

Description:

The key length or key start position is invalid.

Measures:

Set values which make the sum of the key start position and the key length 19998 or less.

HUL2714

KEY VALUE DUPLICATION

Description:

Key values have been duplicated.

Measures:

Assign a unique value to each Key.

HUL2715

BAD MFMTID

Description:

The multi format ID is incorrect.

Measures:

Enter the multi format ID in alphanumeric characters within 50 bytes, which begin with an alphabetic character.

HUL2716

BAD DEFAULT FMTID

Description:

The default format ID is incorrect.

Measures:

Enter the default format ID in alphanumeric characters within 50 bytes, which begin with an alphabetic character.

HUL2717

BAD FMTID

Description:

The format ID is incorrect.

Measures:

Enter the format ID in alphanumeric characters within 50 bytes, which begin with an alphabetic character.