Send Storage Management Information settings

In HULFT Cloud Storage Option Ver.8.5.1 or higher, you can use the individual settings or default settings of the transfer-related information for a send file according to actual operations.

Specify the individual settings or default settings for a send file in the Send Storage Management Information.

The settings of the Send Storage Management Information that can be used to configure the individual settings or default settings are shown below.

  • When configuring the individual settings

    You can configure the settings of the transfer-related information per send file (individual settings) by registering values in the Send Storage Management Information on the Cloud Storage DB.

    If you specify a Send Storage Management Information ID for File Name in the Send Management Information, the individual settings information registered for the ID is used.

  • When configuring the default settings

    You can configure the settings that are used in common when individual settings are not specified (the default settings) by registering values in the default information for the Send Storage Management Information on the Cloud Storage DB.

    If the Send Storage Management Information is not specified (including cases where part of the information is not specified), the default information is used when a send file is downloaded.

 

For the Send Storage Management Information and the default information, you can register only the necessary fields instead of registering all fields.

If you do not register a value in the Send Storage Management Information, the value registered in the default information is used.

If you do not register a default value, the value in the downward-compatible settings is used.

 

The transfer-related information that can be set to the Send Storage Management Information or the default information is shown below.

Table 2.19 Transfer-related information that can be set to Send Storage Management Information and default information

Field Name

Whether It Can Be Omitted

Send Storage Management Information ID

(*1)

Bucket Name or Container Name

✓ (*1)

Storage Timeout

Maximum number of parallels per transfer

Part Size

Storage Authentication Information ID

Region

✓ (*2)

Endpoint URL

✓ (*2)(*3)

:

Optional

Blank

:

Mandatory

*1

:

In the default information, this field does not exist and cannot be set.

*2

:

This field can be set only when you use Amazon S3.

*3

:

This field can be set in HULFT Cloud Storage Option Ver.8.5.3 or higher.

 

For details on the fields, refer to Utilities of HULFT Cloud Storage Option.

For details on the supported regions for Region, refer to Regions for which operation of Amazon S3 has been verified.

Note
  • Use a bucket name or container name for the Send Storage Management Information ID.

  • You can check the bucket name or container name of the download source from Send File Name in the Send Log by using the bucket name or container name for the Send Storage Management Information ID in Send File Name.

  • If you specify a Storage Authentication Information ID that does not exist in the Send Storage Management Information, a read error occurs. Use a registered Storage Authentication Information ID.

    For details on the Storage Authentication Information settings, refer to Storage Authentication Information settings.

 

For usage examples of the utilities to register a timeout value in the individual settings or the default settings, refer to the following:

 

Registering or deleting the Send Storage Management Information

For the Send Storage Management Information, check the settings by using the output command included in the HULFT Cloud Storage Option utilities, and then register or delete the content.

For details on the HULFT Cloud Storage Option utilities, refer to Utilities of HULFT Cloud Storage Option.