Details of Issues

For details on the issues, refer to the link shown under "Management Number."

Severity level: A (critical)

Common

Management Number

Brief Description

Affected Versions

Modified Version

HULFT-28982

When a record of the Format Information is saved for the first time or updated with Start Position omitted, an automatically calculated value is registered

8.4.0 - 8.4.6

10.2.0

Receiving functions

Management Number

Brief Description

Affected Versions

Modified Version

HULFT-27780

In receiving with receiving-side conversion specified, half-width yen symbols in the transferred data may be converted to half-width backslashes

7.0.0 - 8.4.6

10.2.0

 

Utilities

Management Number

Brief Description

Affected Versions

Modified Version

HULFT-27780

When a joined file is split using Joined File Split (XRBREAK), half-width yen symbols in data joined to the file may be converted to half-width backslashes

7.0.0 - 8.4.6

10.2.0

Severity level: B (high)

Common

Management Number

Brief Description

Affected Versions

Modified Version

HULFT-27502

If in the message filter file a message is specified not to be output, when you use HULFT functions, unexpected behaviors such as unsuccessful end may occur

8.4.0 - 8.4.6

10.2.0

 

Receiving functions

Management Number

Brief Description

Affected Versions

Modified Version

HULFT-24291

When unexpected data is received at a port in use by the Receive program (XRRCV) and causes a communication error, an unintended value is displayed in the error message

8.1.0 - 8.4.6

10.2.0