XRSYSIN definition card error messages
- XRP0001
-
PORT IS FROM 1 TO 65535. IGNORE
- Description:
-
There is an error in the defined PORTNO parameter card. (ML=W)
- Measures:
-
Check if the parameter is set as a value from '1' to '65535.'
- XRP0003
-
UNIT NAME IS INVALID. IGNORE
- Description:
-
There is an error in the defined UNIT parameter card. (ML=W)
- Measures:
-
Check if the UNIT name that has been specified is 8 characters or less.
- XRP0004
-
STARTED TASK NAME IS INVALID. IGNORE
- Description:
-
There is an error in the defined START-TASK parameter card. (ML=W)
- Measures:
-
Check if the job name that has been specified is 8 characters or less. Also, make sure if the string begins with an uppercase alphabetic character.
- XRP0005
-
TASK COUNT IS FROM 1 TO 100. IGNORE
- Description:
-
There is an error in the defined TASK-CNT parameter card. (ML=W)
- Measures:
-
Check if the parameter is specified as a value from '1' to '100.'
- XRP0008
-
TASK ABNORMAL IS 'ABEND' OR 'CONTINUE'. IGNORE
- Description:
-
There is an error in the defined TASK-ABEND parameter card. (ML=W)
- Measures:
-
Check if the parameter is specified as either 'CONTINUE' or 'ABEND.'
- XRP0009
-
THIS PARAMETER IS UNDEFINED. paracard
- paracard:
-
Content of the parameter card
- Description:
-
An unknown parameter card was defined. (ML=W)
- Measures:
-
Specify a defined parameter card.
- XRP0010
-
XRSYSIN DD STATEMENT MISSING
- Description:
-
XRSYSIN DD is not specified. (ML=W)
- XRP0011
-
HOSTNAME IS INVALID. IGNORE
- Description:
-
There is an error in the defined HOST-NAME parameter card. (ML=W)
- Measures:
-
Check if the Host Name that has been specified is 8 characters or less. Also, make sure if the string begins with an uppercase alphabetic character.
- XRP0012
-
DATA COUNT CHECK PARAMETER IS 'Y' OR 'N'. IGNORE
- Description:
-
There is an error in the defined DATACHK parameter card. (ML=W)
- Measures:
-
Check if the parameter is specified as either 'Y' or 'N.'
- XRP0013
-
RETRY IS FROM 0 TO 32760. IGNORE
- Description:
-
There is an error in the defined RETRY parameter card. (ML=W)
- Measures:
-
Check if the parameter is specified as a value from '0' to '32760.'
- XRP0014
-
QUEUE SCRATCH PARAMETER IS 'Y' OR 'N'. IGNORE
- Description:
-
There is an error in the defined QDEL parameter card. (ML=W)
- Measures:
-
Check if the parameter is specified as either 'Y' or 'N.'
- XRP0015
-
DOMAIN NAME IS INVALID. IGNORE
- Description:
-
There is an error in the defined DOMAIN parameter card. (ML=W)
- Measures:
-
Check if the Domain name that has been specified is 68 characters or less. Also, make sure if the string begins with an uppercase alphabetic character.
- XRP0016
-
PREFIX IS INVALID. IGNORE
- Description:
-
There is an error in the defined PREFIX parameter card. (ML=W)
- Measures:
-
Check if the First Modifier of Send Work Files that has been specified is 8 characters or less. Also, make sure if the string begins with an uppercase alphabetic character.
- XRP0017
-
HOST CHARA IS UPPER OR LOWER CHARA. IGNORE
- Description:
-
There is an error in the defined HSTCHA parameter card. The parameter will be set as the default value of 'L.' (ML=W)
- Measures:
-
Check if the parameter is specified as either 'U' (Upper case) or 'L' (Lower case).
- XRP0018
-
COMPRESS WORK FILE IS FROM 500 TO 32760. IGNORE
- Description:
-
There is an error in the defined CMPBLK parameter card. The parameter will be set as the default value of '32760.' (ML=W)
- Measures:
-
Check if the parameter is specified as a value from '500' to '32760.'
- XRP0019
-
RECLEN PARAMATER IS 'Y' OR 'N'. IGNORE
- Description:
-
There is an error in the defined RECLEN parameter card. The parameter will be set as the default value of 'N.' (ML=W)
- Measures:
-
Check if the parameter is specified as either 'Y' or 'N.'
- XRP0020
-
JOB-TIME IS FROM 0 TO 1440. IGNORE
- Description:
-
There is an error in the defined JOBTIME parameter card. The parameter will be set as the default value of '15.' (ML=W)
- Measures:
-
Check if the parameter is specified as a value from '0' to '1440.'
- XRP0021
-
PSCHG PARAMETER IS 0 ,1 ,B ,F ,9 ,S ,N;USE INITIAL VALUE 0
- Description:
-
There is an error in the defined PSCHG parameter card. The parameter will be set as the default value of '0.' (ML=W)
- Measures:
-
Check if the parameter is specified as '0,' '1,' 'B,' 'F,' '9,' 'S,' or 'N.'
- XRP0022
-
PSASCII PARAMETER IS '1' OR '2';USE INITIAL VALUE 1
- Description:
-
There is an error in the defined PSASCII parameter card. The parameter will be set as the default value of '1.' (ML=W)
- Measures:
-
Check if the parameter is specified as either '1' or '2.'
- XRP0023
-
PSEBCDIC PARAMETER IS '1' OR '2';USE INITIAL VALUE 1
- Description:
-
There is an error in the defined PSEBSDIC parameter card. The parameter will be set as the default value of '1.' (ML=W)
- Measures:
-
Check if the parameter is specified as either '1' or '2.'
- XRP0024
-
DYNAMIC-DIRECT PARAMETER IS 'Y' OR 'N';USE INITIAL VALUE N
- Description:
-
There is an error in the defined DYNAMIC-DIRECT parameter card. The parameter will be set as the default value of 'N.' (ML=W)
- Measures:
-
Check if the parameter is specified as either 'Y' or 'N.'
- XRP0025
-
SCANMODE PARAMETER IS N OR A;USE INITIAL VALUE N
- Description:
-
There is an error in the defined SCANMODE parameter card. The parameter will be set as the default value of 'N.' (ML=W)
- Measures:
-
Check if the parameter is specified as either 'A' or 'N.'
- XRP0026
-
WORKVOLMODE PARAMETER IS '0' OR '1';USE INITIAL VALUE 0
- Description:
-
There is an error in the defined WORKVOLMODE parameter card. The parameter will be set as the default value of '0.' (ML=W)
- Measures:
-
Check if the parameter is specified as either '0' or '1.'
- XRP0027
-
ENDERRMODE PARAMETER IS '0' OR '1';USE INITIAL VALUE 0
- Description:
-
There is an error in the defined ENDERRMODE parameter card. The parameter will be set as the default value of '0.' (ML=W)
- Measures:
-
Check if the parameter is specified as either '0' or '1.'
- XRP0028
-
TGRPCHK PARAMETER IS FROM 0 TO 2;USE INITIAL VALUE 0
- Description:
-
There is an error in the defined TGRPCHK parameter card. The parameter will be set as the default value of '0.' (ML=W)
- Measures:
-
Check if the parameter is specified as '0,' '1,' or '2.'
- XRP0029
-
HSTCHK PARAMETER IS '0' OR '1';USE INITIAL VALUE 0
- Description:
-
There is an error in the defined HSTCHK parameter card. The parameter will be set as the default value of '0.' (ML=W)
- Measures:
-
Check if the parameter is specified as either '0' or '1.'
- XRP0030
-
INIT-UNIT IS INVALID;USE INITIAL VALUE 'SYSDA'
- Description:
-
There is an error in the defined INIT-UNIT parameter card. The parameter will be set as the default value of 'SYSDA.' (ML=W)
- Measures:
-
Check if the INIT-UNIT name that has been specified is 8 characters or less.
- XRP0031
-
JLIB1 IS INVALID
- Description:
-
There is an error in the defined JLIB1 parameter card. (ML=W)
- Measures:
-
Check if the parameter is set according to the naming conventions for the data set.
- XRP0032
-
JLIB2 IS INVALID
- Description:
-
There is an error in the defined JLIB2 parameter card. (ML=W)
- Measures:
-
Check if the parameter is set according to the naming conventions for the data set.
- XRP0033
-
JLIB3 IS INVALID
- Description:
-
There is an error in the defined JLIB3 parameter card. (ML=W)
- Measures:
-
Check if the parameter is set according to the naming conventions for the data set.
- XRP0034
-
JELIB1 IS INVALID
- Description:
-
There is an error in the defined JELIB1 parameter card. (ML=W)
- Measures:
-
Check if the parameter is set according to the naming conventions for the data set.
- XRP0035
-
JELIB2 IS INVALID
- Description:
-
There is an error in the defined JELIB2 parameter card. (ML=W)
- Measures:
-
Check if the parameter is set according to the naming conventions for the data set.
- XRP0036
-
JELIB3 IS INVALID
- Description:
-
There is an error in the defined JELIB3 parameter card. (ML=W)
- Measures:
-
Check if the parameter is set according to the naming conventions for the data set.
- XRP0037
-
JCAT1 IS INVALID
- Description:
-
There is an error in the defined JCAT1 parameter card. (ML=W)
- Measures:
-
Check if the parameter is set according to the naming conventions for the data set.
- XRP0038
-
JCAT2 IS INVALID
- Description:
-
There is an error in the defined JCAT2 parameter card. (ML=W)
- Measures:
-
Check if the parameter is set according to the naming conventions for the data set.
- XRP0039
-
JCAT3 IS INVALID
- Description:
-
There is an error in the defined JCAT3 parameter card. (ML=W)
- Measures:
-
Check if the parameter is set according to the naming conventions for the data set.
- XRP0040
-
JECAT1 IS INVALID
- Description:
-
There is an error in the defined JECAT1 parameter card. (ML=W)
- Measures:
-
Check if the parameter is set according to the naming conventions for the data set.
- XRP0041
-
JECAT2 IS INVALID
- Description:
-
There is an error in the defined JECAT2 parameter card. (ML=W)
- Measures:
-
Check if the parameter is set according to the naming conventions for the data set.
- XRP0042
-
JECAT3 IS INVALID
- Description:
-
There is an error in the defined JECAT3 parameter card. (ML=W)
- Measures:
-
Check if the parameter is set according to the naming conventions for the data set.
- XRP0046
-
CLEARMODE PARAMETER IS SNDBEFORE OR SNDAFTER;USE INITIAL VALUE SNDBEFORE
- Description:
-
There is an error in the defined CLEARMODE parameter card. The parameter will be set as the default value of 'B.' (ML=W)
- Measures:
-
Check if the parameter is specified as either 'A' or 'B.'
- XRP0047
-
JESC IS INVALID; USE INITIAL VALUE '$'
- Description:
-
There is an error in the defined JESC parameter card. The parameter will be set as the default value of '$.' (ML=W)
- Measures:
-
Specify 1 byte in alphanumeric characters or symbols.
- XRP0048
-
SNDRETRY PARAMETER IS FROM 0 TO 9999;USE INITIAL VALUE 10
- Description:
-
There is an error in the defined SNDRETRY parameter card. The parameter will be set as the default value of '10.' (ML=W)
- Measures:
-
Check if the parameter is specified as a value from '0' to '9999.'
- XRP0049
-
SNDRTIME PARAMETER IS FROM 0 TO 1440;USE INITIAL VALUE 10
- Description:
-
There is an error in the defined SNDRTIME parameter card. The parameter will be set as the default value of '10.' (ML=W)
- Measures:
-
Check if the parameter is specified as a value from '0' to '1440.'
- XRP0050
-
EUCSP PARAMETER IS '0' OR '1';USE INITIAL VALUE 1
- Description:
-
There is an error in the defined EUCSP parameter card. The parameter will be set as the default value of '1.' (ML=W)
- Measures:
-
Check if the parameter is specified as either '0' or '1.'
- XRP0051
-
SNDBNO PARAMETER IS FROM 1 TO 255;USE INITIAL VALUE 5
- Description:
-
There is an error in the defined SNDBNO parameter card. The parameter will be set as the default value of '5.' (ML=W)
- Measures:
-
Check if the parameter is specified as a value from '1' to '255.'
- XRP0052
-
RCVBNO PARAMETER IS FROM 1 TO 255;USE INITIAL VALUE 5
- Description:
-
There is an error in the defined RCVBNO parameter card. The parameter will be set as the default value of '5.' (ML=W)
- Measures:
-
Check if the parameter is specified as a value from '1' to '255.'
- XRP0053
-
INTRCNT PARAMETER IS FROM 0 TO 999;USE INITIAL VALUE 3
- Description:
-
There is an error in the defined INTRCNT parameter card. The parameter will be set as the default value of '3.' (ML=W)
- Measures:
-
Check if the parameter is specified as a value from '0' to '999.'
- XRP0054
-
INTRTIME PARAMETER IS FROM 0 TO 9999;USE INITIAL VALUE 10
- Description:
-
There is an error in the defined INTRTIME parameter card. The parameter will be set as the default value of '10.' (ML=W)
- Measures:
-
Check if the parameter is specified as a value from '0' to '9999.'
- XRP0055
-
RCVOVER-RTY PARAMETER IS '0' OR '1';USE INITIAL VALUE 0
- Description:
-
There is an error in the defined RCVOVER-RTY parameter card. The parameter will be set as the default value of '0.' (ML=W)
- Measures:
-
Check if the parameter is specified as either '0' or '1.'
- XRP0056
-
EBCDIC PARAMETER IS '0' OR '1';USE INITIAL VALUE 0
- Description:
-
There is an error in the defined EBCDIC parameter card. The parameter will be set as the default value of '0.' (ML=W)
- Measures:
-
Check if the parameter is specified as either '0' or '1.'
- XRP0057
-
STATUSDISPLAY PARAMETER IS '0' OR '1';USE INITIAL VALUE 1
- Description:
-
There is an error in the defined STATUSDISPLAY parameter card. The parameter will be set as the default value of '1.' (ML=W)
- Measures:
-
Check if the parameter is specified as either '0' or '1.'
- XRP0058
-
LOGDELTHRESHOLD PARAMETER IS FROM 0 TO 999999;USE INITIAL VALUE 0
- Description:
-
There is an error in the defined LOGDELTHRESHOLD parameter card. The parameter will be set as the default value of '0.' (ML=W)
- Measures:
-
Check if the parameter is specified as a value from '0' to '999999.'
- XRP0059
-
LOGKEEPCOUNT PARAMETER IS FROM 0 TO 999999
- Description:
-
There is an error in the defined LOGKEEPCOUNT parameter card. The log record will not be deleted. (ML=W)
- Measures:
-
Check if the parameter is specified as a value from '0' to '999999.'
- XRP0060
-
GAIJIFILE PARAMETER IS '0' OR '1';USE INITIAL VALUE 0
- Description:
-
There is an error in the defined GAIJIFILE parameter card. The parameter will be set as the default value of '0.' (ML=W)
- Measures:
-
Check if the parameter is specified as either '0' or '1.'
- XRP0061
-
GAIJIERR PARAMETER IS '0' OR '1';USE INITIAL VALUE 0
- Description:
-
There is an error in the defined GAIJIERR parameter card. The parameter will be set as the default value of '0.' (ML=W)
- Measures:
-
Check if the parameter is specified as either '0' or '1.'
- XRP0063
-
SOCKERR-AUTORETRY PARAMETER IS FROM 0 TO 9;USE INITIAL VALUE 0
- Description:
-
There is an error in the defined SOCKERR-AUTORETRY parameter card. The parameter will be set as the default value of '0.' (ML=W)
- Measures:
-
Check if the parameter is specified as a value from '0' to '9.'
- XRP0064
-
RETRYTIME PARAMETER IS FROM 0 TO 99999;USE INITIAL VALUE 0
- Description:
-
There is an error in the defined RETRYTIME parameter card. The parameter will be set as the default value of '0.' (ML=W)
- Measures:
-
Check if the parameter is specified as a value from '0' to '99999.'
- XRP0065
-
MSGDYNPARM PARAMETER IS FROM 0 TO 3;USE INITIAL VALUE 3
- Description:
-
There is an error in the defined MSGDYNPARM parameter card. The parameter will be set as the default value of "3". (ML=W)
- Measures:
-
Check if the parameter is specified as a value from '0' to '3.'
- XRP0066
-
LOGKEEPCOUNT IS NOT SPECIFIED
- Description:
-
The LOGKEEPCOUNT parameter card is not defined. (ML=W)
- Measures:
-
This field is required when the LOGDELTHRESHOLD parameter is specified. Check both fields.
- XRP0067
-
LOGKEEPCOUNT IS GREATER THAN LOGDELTHRESHOLD
- Description:
-
The value for LOGKEEPCOUNT exceeds the value for LOGDELTHRESHOLD. (ML=W)
- Measures:
-
Specify a value for the Log Keep Count that is less than the value for the Log Deletion Threshold.
- XRP0068
-
JLIB1 IS NOT SPECIFIED;IGNORE
- Description:
-
The JLIB1 parameter card is not defined. (ML=W)
- Measures:
-
You can specify up to 3 libraries for STEPLIB. Check if they are specified in order, starting with JLIB1.
- XRP0069
-
JELIB1 IS NOT SPECIFIED;IGNORE
- Description:
-
The JELIB1 parameter card is not defined. (ML=W)
- Measures:
-
You can specify up to 3 libraries for STEPLIB. Check if they are specified in order, starting with JELIB1.
- XRP0070
-
JCAT1 IS NOT SPECIFIED;IGNORE
- Description:
-
The JCAT1 parameter card is not defined. (ML=W)
- Measures:
-
You can specify up to 3 catalog data sets for STEPCAT. Check if they are specified in order, starting with JCAT1.
- XRP0071
-
JECAT1 IS NOT SPECIFIED;IGNORE
- Description:
-
The JECAT1 parameter card is not defined. (ML=W)
- Measures:
-
You can specify up to 3 catalog data sets for STEPCAT. Check if they are specified in order, starting with JECAT1.
- XRP0072
-
CIPHERTYPE PARAMETER IS '0' OR '1';USE INITIAL VALUE 0
- Description:
-
There is an error in the defined CIPHERTYPE parameter card. The parameter will be set as the default value of '0.' (ML=W)
- Measures:
-
Check if the parameter is specified as either '0' or '1.'
- XRP0098
-
TIMEOUT IS INVALID. IGNORE
- Description:
-
There is an error in the defined TIMEOUT parameter card. (ML=W)
- Measures:
-
Check if the time-out is specified as the correct value.
- XRP0099
-
TCPIP ADDRESS SPACE NAME IS INVALID. IGNORE
- Description:
-
There is an error in the defined TCPIP parameter card. (ML=W)
- Measures:
-
Check if the parameter that has been specified is 8 characters or less.
- XRP0100
-
RECEIVE TASK NAME IS INVALID. IGNORE
- Description:
-
There is an error in the defined RECV-TASK parameter card. The parameter will be set as the default value of 'HULRCV.' (ML=W)
- Measures:
-
Check if an alphanumeric value of 8 characters or less has been specified.
- XRP0101
-
PRODUCTKEY IS INVALID. IGNORE
- Description:
-
There is an error in the defined PRODUCTKEY parameter card. (ML=E)
- Measures:
-
Check if the parameter is specified as the correct value.
- XRP0102
-
SERIALNO IS INVALID. IGNORE
- Description:
-
There is an error in the defined SERIALNO parameter card. (ML=E)
- Measures:
-
Check if the parameter is specified as the correct value.
- XRP0103
-
JOBNM IS INVALID. IGNORE
- Description:
-
There is an error in the defined JOBNM parameter card. (ML=W)
- Measures:
-
Check if the parameter is specified as the correct value of 8 bytes.
- XRP0104
-
MSGCLASS IS INVALID;USE INITIAL VALUE B
- Description:
-
There is an error in the defined MSGCLASS parameter card. The parameter will be set as the default value of 'B.' (ML=W)
- Measures:
-
Check if the parameter is specified as the correct value of 1 byte.
- XRP0105
-
CLASS IS INVALID;USE INITIAL VALUE A
- Description:
-
There is an error in the defined CLASS parameter card. The parameter will be set as the default value of 'A.' (ML=W)
- Measures:
-
Check if the parameter is specified as the correct value of 1 byte.
- XRP0106
-
JOBOP1 IS INVALID. IGNORE
- Description:
-
There is an error in the defined JOBOP1 parameter card. (ML=W)
- Measures:
-
Check if the parameter is specified as the correct value of 20 bytes.
- XRP0107
-
JOBOP2 IS INVALID. IGNORE
- Description:
-
There is an error in the defined JOBOP2 parameter card. (ML=W)
- Measures:
-
Check if the parameter is specified as the correct value of 30 bytes.
- XRP0111
-
SAN-VER5 PARAMETER IS 'H' OR 'F'.USE INITIAL VALUE H
- Description:
-
There is an error in the defined SAN-VER5 parameter card. The parameter will be set as the default value of 'H.' (ML=W)
- Measures:
-
Check if the parameter is specified as either 'H' or 'F.'
- XRP0112
-
RESENDDEL PARAMETER IS 0, 1, 2, 3, 9;USE INITIAL VALUE 0
- Description:
-
There is an error in the defined RESENDDEL parameter card. The parameter will be set as the default value of '0.' (ML=W)
- Measures:
-
Check if the parameter is specified as '0,' '1,' '2,' '3,' or '9.'
- XRP0114
-
REQWAITMODE PARAMETER IS '0' OR '1';USE INITIAL VALUE 0
- Description:
-
There is an error in the defined REQWAITMODE parameter card. The parameter will be set as the default value of '0.' (ML=W)
- Measures:
-
Check if the parameter is specified as either '0' or '1.'
- XRP0115
-
CONSMSG LENGTH OVER
- Description:
-
The value exceeds the byte count that can be defined on the CONSMSG parameter card. The portion of the string up to the maximum byte count that can be defined on the CONSMSG parameter card will be set for the parameter. (ML=W)
- XRP0116
-
DEFER PARAMETER IS '0' OR '1';USE INITIAL VALUE 0
- Description:
-
There is an error in the defined DEFER parameter card. The parameter will be set as the default value of '0.' (ML=W)
- Measures:
-
Check if the parameter is specified as either '0' or '1.'
- XRP0117
-
APTHSTCHK PARAMETER IS '0' OR '1';USE INITIAL VALUE 0
- Description:
-
There is an error in the defined APTHSTCHK parameter card. The parameter will be set as the default value of '0.' (ML=W)
- Measures:
-
Check if the parameter is specified as either '0' or '1.'
- XRP0118
-
USRIDCHKMODE PARAMETER IS '0' OR '1';USE INITIAL VALUE 0
- Description:
-
There is an error in the defined USRIDCHKMODE parameter card. The parameter will be set as the default value of '0.' (ML=W)
- Measures:
-
Check if the parameter is specified as either '0' or '1.'
- XRP0122
-
PROCTRANSTYPE PARAMETER IS N,S,R,A;USE INITIAL VALUE A
- Description:
-
There is an error in the defined PROCTRANSTYPE parameter card. The parameter will be set as the default value of 'A.' (ML=W)
- Measures:
-
Check if the parameter is specified as 'N,' 'S,' 'R,' or 'A.'
- XRP0124
-
OPLSELECT PARAMETER IS FROM 0 TO 3;USE INITIAL VALUE 0
- Description:
-
There is an error in the defined OPLSELECT parameter card. The parameter will be set as the default value of '0.' (ML=W)
- Measures:
-
Check if the parameter is specified as a value from '0' to '3.'
- XRP0125
-
OPLCMD1 PARAMETER IS INVALID
- Description:
-
There is an error in the defined OPLCMD1 parameter card. (ML=W)
- Measures:
-
Check if the parameter is set according to the naming conventions for the data set.
- XRP0126
-
OPLCMD2 PARAMETER IS INVALID
- Description:
-
There is an error in the defined OPLCMD2 parameter card. (ML=W)
- Measures:
-
Check if the parameter is set according to the naming conventions for the data set.
- XRP0127
-
PARAMETER VALUES OF OPLCMD1 AND OPLCMD2 ARE THE SAME
- Description:
-
The values defined on the OPLCMD1 parameter card and the OPLCMD2 parameter card are the same. (ML=W)
- Measures:
-
Correctly define the OPLCMD1 parameter card and the OPLCMD2 parameter card.
- XRP0128
-
OPLFILE1 PARAMETER IS INVALID
- Description:
-
There is an error in the defined OPLFILE1 parameter card. (ML=W)
- Measures:
-
Check if the parameter is set according to the naming conventions for the data set.
- XRP0129
-
OPLFILE2 PARAMETER IS INVALID
- Description:
-
There is an error in the defined OPLFILE2 parameter card. (ML=W)
- Measures:
-
Check if the parameter is set according to the naming conventions for the data set.
- XRP0130
-
PARAMETER VALUES OF OPLFILE1 AND OPLFILE2 ARE THE SAME
- Description:
-
The values defined on the OPLFILE1 parameter card and the OPLFILE2 parameter card are the same. (ML=W)
- Measures:
-
Correctly define the OPLFILE1 parameter card and the OPLFILE2 parameter card.
- XRP0131
-
OPLCHARCTER LENGTH OVER
- Description:
-
The value exceeds the byte count that can be defined on the OPLCHARACTER parameter card. The portion of the string up to the maximum byte count that can be defined on the OPLCHARACTER parameter card will be set for the parameter. (ML=W)
- XRP0133
-
JCLRETRY PARAMETER IS FROM 0 TO 9999;USE INITIAL VALUE 0
- Description:
-
There is an error in the defined JCLRETRY parameter card. The parameter will be set as the default value of '0.' (ML=W)
- Measures:
-
Check if the parameter is specified as a value from '0' to '9999.'
- XRP0134
-
JCLRTIME PARAMETER IS FROM 0 TO 1440;USE INITIAL VALUE 0
- Description:
-
There is an error in the defined JCLRTIME parameter card. The parameter will be set as the default value of '0.' (ML=W)
- Measures:
-
Check if the parameter is specified as a value from '0' to '1440.'
- XRP0135
-
OPLCMDBKVOL PARAMETER IS INVALID
- Description:
-
There is an error in the defined OPLCMDBKVOL parameter card. (ML=W)
- Measures:
-
Check if the volume serial number that has been specified is 6 characters or less.
- XRP0136
-
OPLFILEBKVOL PARAMETER IS INVALID
- Description:
-
There is an error in the defined OPLFILEBKVOL parameter card. (ML=W)
- Measures:
-
Check if the volume serial number that has been specified is 6 characters or less.
- XRP0137
-
OPLUNIT PARAMETER IS INVALID
- Description:
-
There is an error in the defined OPLUNIT parameter card. (ML=W)
- Measures:
-
Check if the UNIT name that has been specified is 8 characters or less.
- XRP0138
-
OPLCMDBK PARAMETER IS INVALID
- Description:
-
There is an error in the defined OPLCMDBK parameter card. (ML=W)
- Measures:
-
Check if the parameter is set according to the naming conventions for the data set.
- XRP0139
-
OPLFILEBK PARAMETER IS INVALID
- Description:
-
There is an error in the defined OPLFILEBK parameter card. (ML=W)
- Measures:
-
Check if the parameter is set according to the naming conventions for the data set.
- XRP0140
-
OPLBKJOBNM PARAMETER IS INVALID
- Description:
-
There is an error in the defined OPLBKJOBNM parameter card. (ML=W)
- Measures:
-
Check if the parameter is specified as the correct value of 8 bytes.
- XRP0141
-
HULPRMFILE PARAMETER IS INVALID
- Description:
-
There is an error in the defined HULPRMFILE parameter card. (ML=W)
- Measures:
-
Check if the parameter is set according to the naming conventions for the data set.
- XRP0142
-
PARAMETER VALUES OF OPLCMDBK AND OPLFILEBK ARE THE SAME
- Description:
-
The values defined on the OPLFILEBK parameter card and the OPLCMDBK parameter card are the same. (ML=W)
- Measures:
-
Correctly define the OPLFILEBK parameter card and the OPLCMDBK parameter card.
- XRP0144
-
CNVLENCHK PARAMETER IS '0' OR '1';USE INITIAL VALUE 0
- Description:
-
There is an error in the defined CNVLENCHK parameter card. The parameter will be set as the default value of '0.' (ML=W)
- Measures:
-
Check if the parameter is specified as either '0' or '1.'
- XRP0147
-
SNDSOCKSIZE PARAMETER IS 0 OR FROM 4096 TO 262144;USE INITIAL VALUE 0
- Description:
-
There is an error in the defined SNDSOCKSIZE parameter card. The parameter will be set as the default value of '0.' (ML=W)
- Measures:
-
Check that a value from '4096' to '262144' is set.
- XRP0148
-
RCVSOCKSIZE PARAMETER IS 0 OR FROM 4096 TO 524288;USE INITIAL VALUE 0
- Description:
-
There is an error in the defined RCVSOCKSIZE parameter card. The parameter will be set as the default value of '0.' (ML=W)
- Measures:
-
Check that a value from '4096' to '524288' is set.
- XRP0149
-
DATEFMT PARAMETER IS '1' OR '2' OR '3';USE INITIAL VALUE 1
- Description:
-
There is an error in the defined DATEFMT parameter card. The parameter will be set as the default value of '1.' (ML=W)
- Measures:
-
Check that '1,' '2,' or '3' is set for the Date Format.
- XRP0150
-
HULLANG PARAMETER IS 'JPN' OR 'ENG';USE INITIAL VALUE JPN
- Description:
-
There is an error in the defined HULLANG parameter card. 'JPN' is set as the default value. (ML=W)
- Measures:
-
Check that HULFT Operation Language is set to 'JPN' or 'ENG.'
- XRP0153
-
TTMODE PARAMETER IS '0' OR '1';USE INITIAL VALUE 0
- Description:
-
There is an error in the defined TTMODE parameter card. The parameter will be set as the default value of '0.' (ML=W)
- Measures:
-
Check if the parameter is specified as either '0' or '1.'
- XRP0154
-
TTRCVOMIT PARAMETER IS '0' OR '1';USE INITIAL VALUE 0
- Description:
-
There is an error in the defined TTRCVOMIT parameter card. The parameter will be set as the default value of '0.' (ML=W)
- Measures:
-
Check if the parameter is specified as either '0' or '1.'
- XRP0155
-
TTRCVFILOUTPUT PARAMETER IS '0' OR '1';USE INITIAL VALUE 0
- Description:
-
There is an error in the defined TTRCVFILOUTPUT parameter card. The parameter will be set as the default value of '0.' (ML=W)
- Measures:
-
Check if the parameter is specified as either '0' or '1.'
- XRP0156
-
TTPRESNDJOB PARAMETER IS '0' OR '1' OR '2';USE INITIAL VALUE 0
- Description:
-
There is an error in the defined TTPRESNDJOB parameter card. The parameter will be set as the default value of '0.' (ML=W)
- Measures:
-
Check that '0,' '1,' or '2' is set.
- XRP0157
-
TTSNDJOB PARAMETER IS '0' OR '1' OR '2';USE INITIAL VALUE 0
- Description:
-
There is an error in the defined TTSNDJOB parameter card. The parameter will be set as the default value of '0.' (ML=W)
- Measures:
-
Check that '0,' '1,' or '2' is set.
- XRP0158
-
TTRCVJOB PARAMETER IS '0' OR '1' OR '2';USE INITIAL VALUE 0
- Description:
-
There is an error in the defined TTRCVJOB parameter card. The parameter will be set as the default value of '0.' (ML=W)
- Measures:
-
Check that '0,' '1,' or '2' is set.
- XRP0159
-
TTSNDRCVLOG PARAMETER IS '0' OR '1';USE INITIAL VALUE 1
- Description:
-
There is an error in the defined TTSNDRCVLOG parameter card. The parameter will be set as the default value of '1.' (ML=W)
- Measures:
-
Check if the parameter is specified as either '0' or '1.'
- XRP0161
-
SND-SEQNO-THRESHOLD PARAMETER IS FROM 0 TO 999999999999999;USE INITIAL VALUE 0
- Description:
-
There is an error in the defined SND-SEQNO-THRESHOLD parameter card. The parameter will be set as the default value of '0.' (ML=W)
- Measures:
-
Check if the parameter is specified as a value from '0' to '999999999999999.'
- XRP0162
-
RESND-QUELISTNO-THRESHOLD PARAMETER IS FROM 0 TO 99999999;USE INITIAL VALUE 0
- Description:
-
There is an error in the defined RESND-QUELISTNO-THRESHOLD parameter card. The parameter will be set as the default value of '0.' (ML=W)
- Measures:
-
Check if the parameter is specified as a value from "0" to "99999999".
- XRP0163
-
OUTSTSKID PARAMETER IS 'Y' OR 'N';USE INITIAL VALUE N
- Description:
-
There is an error in the defined OUTSTSKID parameter card. The parameter will be set as the default value of 'N.' (ML=W)
- Measures:
-
Check if the parameter is specified as either 'Y' or 'N.'
- XRP0164
-
CNSSELECT PARAMETER IS '0' OR '1';USE INITIAL VALUE 0
- Description:
-
There is an error in the defined CNSSELECT parameter card. The parameter will be set as the default value of '0.' (ML=W)
- Measures:
-
Check if the parameter is specified as either '0' or '1.'
- XRP0165
-
RPREFIX IS INVALID. IGNORE
- Description:
-
There is an error in the defined RPREFIX parameter card. (ML=W)
- Measures:
-
Check if the RPREFIX name that has been specified is 8 characters or less.
- XRP0167
-
TERMLICENSEKEY IS INVALID. IGNORE
- Description:
-
There is an error in the defined TERMLICENSEKEY parameter card. (ML=E)
- Measures:
-
Check if the parameter is specified as the correct value.
- XRP0168
-
HULCHARSET PARAMETER IS INVALID;USE INITIAL VALUE 939
- Description:
-
There is an error in the defined HULCHARSET parameter card. The parameter will be set as the default value of '939.' (ML=W)
- Measures:
-
Specify the CCSID (Coded Character Set Identifier) value of the emulator in use. Refer to Administration Manual for details.
- XRP0169
-
CS4TRNSFR PARAMETER IS INVALID;USE INITIAL VALUE I
- Description:
-
There is an error in the defined CS4TRNSFR parameter card. The parameter will be set as the default value of 'I.' (ML=W)
- Measures:
-
Check if the parameter is specified as"I."
- XRP0170
-
OPLEBCDIC PARAMETER IS A ,B ,E ,F ,H
- Description:
-
There is an error in the defined OPLEBCDIC parameter card. (ML=W)
- Measures:
-
Check if the parameter is specified as 'A,' 'B,' 'E,' 'F,' or 'H.'
- XRP0171
-
INDOPTVAR PARAMETER IS '0' OR '1';USE INITIAL VALUE 0
- Description:
-
There is an error in the defined INDOPTVAR parameter card. The parameter will be set as the default value of '0.' (ML=W)
- Measures:
-
Check if the parameter is specified as either '0' or '1.'
- XRP0172
-
LISTEN PARAMETER IS 0 OR FROM 1 TO 2147483647;USE INITIAL VALUE 0
- Description:
-
There is an error in the defined LISTEN parameter card. The parameter will be set as the default value of '0.' (ML=W)
- Measures:
-
Check if the parameter is specified as a value from '0' to '2147483647.'
- XRP0173
-
SND-START-MODE IS INVALID;USE INITIAL VALUE WARM
- Description:
-
There is an error in the defined SND-START-MODE parameter card. The parameter will be set as the default value of "WARM". (ML=W)
- Measures:
-
Check if the parameter is specified as "WARM", "COLD", "COLD2", or "COLD3".
- XRP0174
-
RCV-APPLNM IS INVALID. IGNORE
- Description:
-
There is an error in the defined RCV-APPLNM parameter card. (ML=W)
- Measures:
-
Check if an alphanumeric value of 8 characters or less has been specified.
- XRP0175
-
RCV-MAXCON PARAMETER IS FROM 1 TO 100;USE INITIAL VALUE 16
- Description:
-
There is an error in the defined RCV-MAXCON parameter card. The parameter will be set as the default value of "16". (ML=W)
- Measures:
-
Check if the parameter is specified as a value from '1' to '100.'
- XRP0176
-
RCV-RECCHK PARAMETER IS 'Y' OR 'N';USE INITIAL VALUE N
- Description:
-
There is an error in the defined RCV-RECCHK parameter card. The parameter will be set as the default value of 'N.' (ML=W)
- Measures:
-
Check if the parameter is specified as either 'Y' or 'N.'
- XRP0177
-
RCV-FILE-WAIT PARAMETER IS 'Y' OR 'N';USE INITIAL VALUE N
- Description:
-
There is an error in the defined RCV-FILE-WAIT parameter card. The parameter will be set as the default value of 'N.' (ML=W)
- Measures:
-
Check if the parameter is specified as either 'Y' or 'N.'
- XRP0178
-
RCV-FILE-SEARCH PARAMETER IS 'V' OR 'C';USE INITIAL VALUE V
- Description:
-
There is an error in the defined RCV-FILE-SEARCH parameter card. The parameter will be set as the default value of "V". (ML=W)
- Measures:
-
Check if the parameter is specified as either "V" or "C".
- XRP0179
-
RCV-FILE-RETRY PARAMETER IS FROM 0 TO 9999;USE INITIAL VALUE 0
- Description:
-
There is an error in the defined RCV-FILE-RETRY parameter card. The parameter will be set as the default value of '0.' (ML=W)
- Measures:
-
Check if the parameter is specified as a value from '0' to '9999.'
- XRP0180
-
RCV-FILE-RTIME PARAMETER IS FROM 0 TO 32760;USE INITIAL VALUE 0
- Description:
-
There is an error in the defined RCV-FILE-RTIME parameter card. The parameter will be set as the default value of '0.' (ML=W)
- Measures:
-
Check if the parameter is specified as a value from '0' to '32760.'
- XRP0181
-
RCV-JOBWTIME PARAMETER IS FROM 1 TO 1440;USE INITIAL VALUE 15
- Description:
-
There is an error in the defined RCV-JOBWTIME parameter card. The parameter will be set as the default value of "15". (ML=W)
- Measures:
-
Check if the parameter is specified as a value from "1" to "1440".
- XRP0182
-
RCV-CHRSET PARAMETER IS '0' OR 'S';USE INITIAL VALUE 0
- Description:
-
There is an error in the defined RCV-CHRSET parameter card. The parameter will be set as the default value of '0.' (ML=W)
- Measures:
-
Check if the parameter is specified as either "0" or "S".
- XRP0184
-
RCV-TIMEOUT PARAMETER IS FROM 10 TO 259200;USE INITIAL VALUE 3600
- Description:
-
There is an error in the defined RCV-TIMEOUT parameter card. The parameter will be set as the default value of "3600". (ML=W)
- Measures:
-
Check if the parameter is specified as a value from "10" to "259200".
- XRP0185
-
APT-APPLNM IS INVALID. IGNORE
- Description:
-
There is an error in the defined APT-APPLNM parameter card. (ML=W)
- Measures:
-
Check if an alphanumeric value of 8 characters or less has been specified.
- XRP0186
-
APT-MAXCON PARAMETER IS FROM 1 TO 100;USE INITIAL VALUE 16
- Description:
-
There is an error in the defined APT-MAXCON parameter card. The parameter will be set as the default value of "16". (ML=W)
- Measures:
-
Check if the parameter is specified as a value from '1' to '100.'
- XRP0188
-
APT-TIMEOUT PARAMETER IS FROM 10 TO 259200;USE INITIAL VALUE 3600
- Description:
-
There is an error in the defined APT-TIMEOUT parameter card. The parameter will be set as the default value of "3600". (ML=W)
- Measures:
-
Check if the parameter is specified as a value from "10" to "259200".
- XRP0189
-
ALLOWSNDREQ PARAMETER IS 'Y' OR 'N';USE INITIAL VALUE Y
- Description:
-
There is an error in the defined ALLOWSNDREQ parameter card. The parameter will be set as the default value of "Y". (ML=W)
- Measures:
-
Check if the parameter is specified as either 'Y' or 'N.'
- XRP0190
-
ALLOWPOSTRJOBRSLT PARAMETER IS 'Y' OR 'N';USE INITIAL VALUE Y
- Description:
-
There is an error in the defined ALLOWPOSTRJOBRSLT parameter card. The parameter will be set as the default value of "Y". (ML=W)
- Measures:
-
Check if the parameter is specified as either 'Y' or 'N.'
- XRP0191
-
ALLOWJOBRSLTNTFY PARAMETER IS 'Y' OR 'N';USE INITIAL VALUE Y
- Description:
-
There is an error in the defined ALLOWJOBRSLTNTFY parameter card. The parameter will be set as the default value of "Y". (ML=W)
- Measures:
-
Check if the parameter is specified as either 'Y' or 'N.'
- XRP0192
-
ALLOWRMTJOBEXE PARAMETER IS 'Y' OR 'N';USE INITIAL VALUE Y
- Description:
-
There is an error in the defined ALLOWRMTJOBEXE parameter card. The parameter will be set as the default value of "Y". (ML=W)
- Measures:
-
Check if the parameter is specified as either 'Y' or 'N.'
- XRP0193
-
ALLOWINSTTRANS PARAMETER IS 'Y' OR 'N';USE INITIAL VALUE Y
- Description:
-
There is an error in the defined ALLOWINSTTRANS parameter card. The parameter will be set as the default value of "Y". (ML=W)
- Measures:
-
Check if the parameter is specified as either 'Y' or 'N.'
- XRP0194
-
INSTTRANSCODCNV PARAMETER IS 'S' OR 'R';USE INITIAL VALUE R
- Description:
-
There is an error in the defined INSTTRANSCODCNV parameter card. The parameter will be set as the default value of "R". (ML=W)
- Measures:
-
Check if the parameter is specified as either "S" or "R".
- XRP0195
-
INSTTRANSEBCDIC PARAMETER IS 0 ,A ,B ,C ,D ,E ,F ,G ,H ,V ,W ,X;USE INITIAL VALUE 0
- Description:
-
There is an error in the defined INSTTRANSEBCDIC parameter card. The parameter will be set as the default value of '0.' (ML=W)
- Measures:
-
Check if the parameter is specified as "0", "A", "B", "C", "D", "E", "F", "G", "H", "V", "W", or "X".
- XRP0197
-
INSTTRANSRCVUNIT PARAMETER IS INVALID
- Description:
-
There is an error in the defined INSTTRANSRCVUNIT parameter card. (ML=W)
- Measures:
-
Check if the parameter is specified as the correct value of 8 digits.
- XRP0198
-
INSTTRANSRCVSPACE IS INVALID;USE INITIAL VALUE (CYL,(5,3),RLSE)
- Description:
-
There is an error in the defined INSTTRANSRCVSPACE parameter card. The parameter will be set as the default value of "(CYL,(5,3),RLSE)". (ML=W)
- Measures:
-
Check if the parameter is specified as the correct value.
- XRP0199
-
INSTTRANSRCVDCB IS INVALID;USE INITIAL VALUE (RECFM=VB,LRECL=256,BLKSIZE=6233)
- Description:
-
There is an error in the defined INSTTRANSRCVDCB parameter card. The parameter will be set as the default value of "(RECFM=VB,LRECL=256,BLKSIZE=6233)". (ML=W)
- Measures:
-
Check if the parameter is specified as the correct value.
- XRP0200
-
INSTTRANSMFRCVORG PARAMETER IS 'S' OR 'R';USE INITIAL VALUE S
- Description:
-
There is an error in the defined INSTTRANSMFRCVORG parameter card. The parameter will be set as the default value of "S". (ML=W)
- Measures:
-
Check if the parameter is specified as either "S" or "R".
- XRP0201
-
INSTTRANSCMDQUE PARAMETER IS INVALID
- Description:
-
There is an error in the defined INSTTRANSCMDQUE parameter card. (ML=W)
- Measures:
-
Check if the parameter is set according to the naming conventions for the data set.
- XRP0202
-
CONSOLELOG PARAMETER IS 000 ,001 ,010 ,011 ,100 ,101 ,110 ,111;USE INITIAL VALUE 111
- Description:
-
There is an error in the defined CONSOLELOG parameter card. The parameter will be set as the default value of "111". (ML=W)
- Measures:
-
Check if the parameter is specified as "000", "001", "010", "011", "100", "101", "110", or "111".
- XRP0203
-
CONS-MSGFILTER PARAMETER IS INVALID
- Description:
-
There is an error in the defined CONS-MSGFILTER parameter card. (ML=W)
- Measures:
-
Check if the parameter is specified as the correct value.
- XRP0204
-
CONTROL-FILE PARAMETER IS INVALID
- Description:
-
There is an error in the defined CONTROL-FILE parameter card. (ML=W)
- Measures:
-
Check if the parameter is specified as the correct value.
- XRP0206
-
RCV-MAXCON PARAMETER MAX OVER ;USE INITIAL VALUE 100
- Description:
-
The value that is defined on the RCV-MAXCON parameter card exceeds the maximum value. The parameter will be set as the default value of "100". (ML=W)
- Measures:
-
Check if the parameter is specified as a value from '1' to '100.'
- XRP0207
-
APT-MAXCON PARAMETER MAX OVER ;USE INITIAL VALUE 100
- Description:
-
The value that is defined on the APT-MAXCON parameter card exceeds the maximum value. The parameter will be set as the default value of "100". (ML=W)
- Measures:
-
Check if the parameter is specified as a value from '1' to '100.'
- XRP0208
-
INSTTRANSDSNLST PARAMETER IS INVALID
- Description:
-
There is an error in the defined INSTTRANSDSNLST parameter card. (ML=W)
- Measures:
-
Check if the parameter is specified as the correct value.
- XRP0209
-
INSTTRANSVOLLST PARAMETER IS INVALID
- Description:
-
There is an error in the defined INSTTRANSVOLLST parameter card. (ML=W)
- Measures:
-
Check if the parameter is specified as the correct value.
- XRP0210
-
STRONGKEYMODE PARAMETER IS '0' OR '1';USE INITIAL VALUE 0
- Description:
-
There is an error in the defined STRONGKEYMODE parameter card. The parameter will be set as the default value of "0". (ML=W)
- Measures:
-
Check if the parameter is specified as either '0' or '1.'
- XRP0212
-
XRHULINS DD STATEMENT MISSING
- Description:
-
XRHULINS DD is not specified. (ML=W)
- Measures:
-
Allocate XRHULINS.
- XRP0213
-
CODE-CONVERSION-LOCATION PARAMETER IS 'ANY' OR '64' OR '31';USE INITIAL VALUE ANY
- Description:
-
There is an error in the defined CODE-CONVERSION-LOCATION parameter card. "ANY" is set as the default value. (ML=W)
- Measures:
-
Check whether "ANY", "64", or "31" is specified as a parameter.
- XRP0215
-
SYSFILEOUTPUTMODE PARAMETER IS '0' OR '1';USE INITIAL VALUE 0
- Description:
-
There is an error in the defined SYSFILEOUTPUTMODE parameter card. The parameter will be set as the default value of '0'. (ML=W)
- Measures:
-
Check if the parameter is specified as either '0' or '1.'
You can use the System Environment Settings Default Value Modification program (XRPRMSET) to change the default values of the System Environment Settings. When making such changes, the default values that are output in XRPxxxx error messages may not be the same as the actual default values. If you have changed the default values, you can use the System Environment Settings Value Output program (XRPRMGEN) to check them.