Execution of Post-send Job and Post-receive Job messages

XRJ0001

JOB INF OPEN ERROR RC=fdbk FILEID=fileid

fdbk:

Detail code for VSAM macro (FDBK)

fileid:

File ID

Description:

Failed to open the Send and Receive Management file. (ML=E)

Measures:

A failure has occurred in the Send and Receive Management file (HULFT.FILE). Refer to the detail code for VSAM and take the appropriate measures.

XRJ0002

JOB ID NOT EXIST JOBID=jobid

jobid:

Job ID

Description:

The Job ID does not exist in the Job Information. (ML=E)

Measures:

Register the Job Information for the appropriate job ID.

XRJ0003

JCL LIBRARY ALLOC ERROR RC=code FILEID=fileid

code:

Error code for DYNALLOC macro

fileid:

File ID

Description:

Failed to allocate the JCL library. (ML=E)

Measures:

The JCL library may not exist, or there could be another cause. Refer to the DYNALLOC macro error codes, and take the appropriate measures.

XRJ0004

JCL LIBRARY OPEN FAILED FILEID=fileid

fileid:

File ID

Description:

Failed to open the JCL library. (ML=E)

Measures:

The file organization attribute of the JCL library may not be Partitioned Organization, or there could be another cause. Check the JCL library.

XRJ0005

JCL MEMBER IS NOT EXIST FILEID=fileid JOBID=jobid

fileid:

File ID

jobid:

Job ID

Description:

The startup job that is registered in the Job Information does not exist. (ML=E)

Measures:

Register the startup job in the Job Information again, or create the startup job.

XRJ0006

JCL MEMBER READ ERROR

Description:

Failed to read the startup job. (ML=E)

Measures:

There may have been an error in the JCL library. Check the JCL library.

XRJ0007

JCL LIBRARY CLOSE FAILED

Description:

Failed to close the JCL library. (ML=E)

Measures:

There may have been an error in the JCL library. Check the JCL library.

XRJ0008

JCL LIBRARY FREE ERROR RC=code

code:

Error code for DYNALLOC macro

Description:

Failed to release the JCL library. (ML=E)

Measures:

Refer to the DYNALLOC macro error codes, and take the appropriate measures.

XRJ0009

INTRDR ALLOCATION ERROR RC=code FILEID=fileid

code:

Error code for DYNALLOC macro

fileid:

File ID

Description:

Failed to allocate the internal reader. (ML=E)

Measures:

This is HULFT system error. Contact your Technical Support Service representative, if you have already concluded the Technical Support Agreement.

XRJ0010

INIRDR OPEN FAILED

Description:

Failed to open the internal reader. (ML=E)

Measures:

This is HULFT system error. Contact your Technical Support Service representative, if you have already concluded the Technical Support Agreement.

XRJ0011

INTRDR CLOSE FAILED

Description:

Failed to close the internal reader. (ML=E)

Measures:

This is HULFT system error. Contact your Technical Support Service representative, if you have already concluded the Technical Support Agreement.

XRJ0012

INTRDR FREE ERROR RC=code

code:

Error code for DYNALLOC macro

Description:

Failed to release the internal reader. (ML=E)

Measures:

This is HULFT system error. Contact your Technical Support Service representative, if you have already concluded the Technical Support Agreement.

XRJ0013

RECEIVE INF GET ERROR

Description:

Failed to read the applicable Receive Management Information records. (ML=E)

Measures:

The applicable Receive Management Information records may have been deleted. Register the applicable information records.

XRJ0014

JOB EXECUTION COMPLETE JOBID=jobid

jobid:

Job ID

Description:

Execution of the job was completed successfully. (ML=I)

XRJ0020

INTRDR ALLOC RETRY

Description:

Could not use the internal reader. Try executing the procedure once again. (ML=W)

XRJ0021

MSGX CONVERSION ERROR FILEID=fileid

fileid:

File ID

Description:

Unable to replace the name of the JCL library that is registered in the Job Information with the specified message. (ML=E)

Measures:

Register the startup job in the Job Information again, or check the MSG of the Send File.

XRJ8005

JCL MEMBER NOT EXIST JOBID=jobid

FILEID=fileid

jobid:

Job ID

fileid:

File ID

Description:

The startup job that is registered in the Job Information does not exist. (ML=E)

Measures:

Register the startup job in the Job Information again, or create the start job.