Detail codes related to SAN
This section describes the detail codes displayed when SAN transfer is used.
100
- Description:
-
Failed to open the Volume Definition file.
- Measure:
-
Confirm that the Volume Definition file exist in the binnt directory and that appropriate permissions to access the file have been set.
101
- Description:
-
Failed to read the Volume Definition file.
- Measure:
-
Check the content of the Volume Definition file.
102
- Description:
-
The Volume Definition file format is invalid.
- Measure:
-
Check the content of the Volume Definition file.
104
- Description:
-
The relevant record is not found in the Volume Definition file.
- Measure:
-
Confirm that volume information configured on Mainframe exists in the Volume Definition file.
200
- Description:
-
Extra records are found in the Send file during the file verification processing.
- Measure:
-
For the sending host, data set records may have been deleted. For the receiving host, data set records may have been added. Confirm that no other process is accessing the data set.
201
- Description:
-
Extra records are found in the Receive file during the file verification processing.
- Measure:
-
For the sending host, data set records may have been added. For the receiving host, data set records may have been deleted. Confirm that no other process is accessing the data set.
202
- Description:
-
Record inconsistency is found during the file verification processing.
- Measure:
-
Data in the data set may have been updated. Confirm that no other process is accessing the data set.
203
- Description:
-
The PROXY setting is found in the Host Information.
- Measure:
-
To carry out SAN transfer, do not specify the PROXY settings.
204
- Description:
-
The Volume Serial Number is not set.
- Measure:
-
Check whether the Volume Serial Number is set correctly in the Receive Management Information on Mainframe.
205
- Description:
-
The Send file size is 2GB or more.
- Measure:
-
SAN transfer cannot transfer files when the file size is 2GB or larger. Use LAN to transfer data.
206
- Description:
-
The Code Conversion is set to 'Receiving Side.'
- Measure:
-
To carry out SAN transfer, specify 'Sending Side' or 'No Conversion' for the Code Conversion in the Send Management Information.
207
- Description:
-
Length of records written to data set is too long.
- Measure:
-
Check the record length of data set and the record length of Send file.
208
- Description:
-
The Host Type of the remote host is invalid.
- Measure:
-
Confirm that 'Mainframe' is set to the Host Type of the remote host registered in the Host Information.
209
- Description:
-
HULFT-SAN(H) has not been installed on the remote host.
- Measure:
-
Confirm that HULFT-SAN(H) is installed on the remote host.
210
- Description:
-
The size specified for FAL does not correspond to the size written to the data set.
- Measure:
-
Confirm that the receiving host has enough data set area.