Job Execution Result Notification command (hulsndrc.exe)

101

Description:

A parameter error occurred.

Measure:

Check whether the entered parameter is correct.

103  Unable to connect. Detail Code=%d

Description:

Connecting of the socket failed.

Measure 1:

Check whether the Observe process on the remote host has been started.

Measure 2:

Set a large value for Connect Retry Count (retrycnt) and Connect Retry Interval (retrytime).

Measure 3:

To acknowledge the request from the remote host, increase the value of Connect Retry Count (retrycnt) in the System Environment Settings file (hulenv.cnf).

104

Description:

An error occurred while sending the data.

Measure:

Verify the communication environment.

105

Description:

An error occurred while receiving data.

Measure:

Verify the communication environment.

106

Description:

The notification receiving host does not exist in the Host Information.

Measure:

Register the notification receiving host in the Host Information

108

Description:

An error occurred while attempting to write to the file.

Measure:

Check available disk space.

109

Description:

An error occurred while receiving data.

Measure:

Verify the communication environment.

110

Description:

Opening of the file failed.

Measure:

Verify the access permissions of the output file.

112

Description:

The processing was canceled from the request destination host.

Measure:

Check the Observe Log file of the request destination host.

113

Description:

An error occurred at the request destination host.

Measure:

Check the Observe Log file of the request destination host.

115

Description:

Insufficient memory.

Measure:

Terminate any unnecessary applications.

116

Description:

An error occurred while accessing the file.

118  Unable to get the IP address.

Description:

An error occurred while obtaining the IP address.

Measure:

Register the IP address in the hosts file or DNS Server.

119  Failed to acquire Date Format.

Description:

Failed to acquire Date Format.

Measure:

Check the setting of Date Format in the System Environment Settings.

120  Failed to acquire HULFT Operation Language.

Description:

Failed to acquire HULFT Operation Language.

Measure:

Check the setting of HULFT Operation Language in the System Environment Settings.

121  Failed to read the System Environment Settings file.

Description:

Reading the System Environment Settings file (hulenv.cnf) failed.

Measure 1:

Check that the System Environment Settings file (hulenv.cnf) exists.

Measure 2:

Check the access permissions for the System Environment Settings file (hulenv.cnf).

122  Error occurred while initializing socket.

Description:

Unable to initialize the socket.

Measure:

Restart the HULFT service.

123  Failed to communicate in the Forced Strong Key mode.

Description:

Failed to communicate in the Forced Strong Key mode.

Measure:

Check that all of the following conditions are met on the destination host:

  • Forced Strong Key mode is enabled

  • HULFT Ver.8.4.0 or higher is installed

  • HULFT8 Cipher Option(AES) is installed

153  An error occurred during character code conversion.

Description:

An error occurred during character code conversion.

Measure:

Insufficient memory.

Terminate any unnecessary applications.

156  Failed to open the Command Message file of the command that you ran.

Description:

Failed to open the Command Message file of the command that you ran.

Measure 1:

Check that the file exists.

Measure 2:

Check the access permissions for the file.

162  Failed to load the encryption exit routine library. (Power-up self-test error = %d)

Description:

Failed in the power-up self-test while loading the encryption exit routine library.

Measure:

The encryption exit routine library may be damaged.