Details of Issues

For details on the issues, refer to the link shown under "Management Number."

Severity level: C (medium)

Table 3.1 Modified version 10.2.0

Management Number

Brief Description

Affected Versions

Modified Version

HULFT-27216

When "Yes" (Y) is specified for Use Regular Expression (REGEX) in the File Trigger Information and one or more multibyte characters specified for the name of a file to be monitored, some characters are incorrectly recognized as regular expression metacharacters

8.1.0 - 8.4.1

10.2.0

Severity level: D (low)

Table 3.2 Modified version 10.2.1

Management Number

Brief Description

Affected Versions

Modified Version

HULFT-29259

When you perform an Update Installation from HULFT8 Manager, unnecessary files remain in the folder after installation

10.2.0

10.2.1

HULFT-29332

"HULFT6 Manager" is displayed as an option on the HULFT Manager Converter screen

10.2.0

10.2.1

HULFT-29469

The English field name of Operation Log Auto Switch Count in the System Environment Settings is displayed incorrectly

8.4.0 - 10.2.0

10.2.1

Table 3.3 Modified version 10.2.0

Management Number

Brief Description

Affected Versions

Modified Version

HULFT-26986

When users who only have Permission to View System Management Information open the Send Management Information Update screen, Format/Multi Format ID (FMTID), Compression Unit (COMPSIZE), and Interface DBID (DBID) show nothing even though a value is set

8.0.0 - 8.4.1

10.2.0