System Environment Settings list

The fields of the System Environment Settings displayed on the System Environment Settings screen are classified as follows:

Note
  • You can use the Scheduler only if the HULFT10 Server grade is installed.

  • You can specify the Shared Settings by HULFT if HULFT10 Server grade is installed.

Table 4.66 System Environment Settings List

Field Name

Tag Name

Default Value

Setting Value

Remarks

Startup

 

Work File Generation Path

tmpdir

.

Characters

Within 200
bytes

Service Port No.

srvport

31001

1–65535

 

Command Acknowledge Port No.

sddport

32000

1–65535

 

Receive Port No.

rcvport

30000

1–65535

 

Observe Port No.

obsport

31000

1–65535

 

Service Process Port No.

srvcprocport

 

1–65535

or no specification

 

Scheduler Port No.

schport

 

1–65535 or
no specification

 

Send Process Multiplex Level

sndpsnum

10

1–999

 

Receive Process Multiplex Level

rcvpsnum

999

1–999

 

Automatic Process Startup

autostart

All selected

(*1)

 

Process Auto Reboot Max. Count

procrestartcnt

0

0–99

 

Process Auto Reboot Retry Interval

procrestarttime

60

0–99

 

Account Name

-

 

Characters

 

Domain Name

-

 

Half-width characters

Within 64 bytes

Password

-

 

Half-width characters

 

Code Conversion

 

Code Set for Transfer

cs4trnsfr

Value set during installation

(*2)

 

Standard for Japanese

jistype

83JIS

(*2)

 

JIS Year

jistype

83JIS

(*2)

 

Tab Code Mode

tabchange

Space

(*2)

 

Use Custom Character Table

gaijifile

Off

(*2)

 

Handling of Unregistered Custom Characters

gaijierr

Default Value

(*2)

 

Code Conversion Mode

codechangemode

Mode 0

(*2)

 

Pack Zone Conversion

pschg

Mode 0

(*2)

 

Sign for ASCII

psascii

Mode 1

(*2)

 

Sign for EBCDIC

psebcdic

Mode 1

(*2)

 

X Type Conversion

xmode

Mode 0

(*2)

 

Instant Transfer Code Converting Side

insttranscodcnv

Receiving Side

(*2)

 

Send and Receive

 

Encryption Scheme

ciphertype

(*3)

(*2)

 

Receive Ready Notification

rcvcmd

No

(*2)

 

Send Unit Selection

sndpsend

Before Starting Subsequent Job

(*2)

 

Transfer Group Check

tgrpchk

No

(*2)

 

Retry Count on Locked Send File

lockcnt

0

0–99999

 

Retry Interval on Locked Send File

locktime

0

0–99999

 

Retry Count on Locked Receive File

rretrycnt

0

0–99999

 

Retry Interval on Locked Receive File

rretrytime

0

0–99999

 

Retry Count on Send File

sretrycnt

10

0–99999

 

Retry Interval on Send File

sretrytime

1

0–99999

 

Dynamic Parameter Specification

dynparam

Enable Dynamic Specification

(*2)

 

Message Dynamic Parameter Specification

msgdynparam

Always Replace Messages and Variables

(*2)

 

Receive Multiplex Level Over Retry

rcvover_rty

Do Not Retry, and Give Error:

(*2)

 

Send Transfer Error Recovery

enderrmode

As Successful End

(*2)

(*4)

Criteria to Delete Resend Queue

resenddel

Mode 1

(*2)

 

Receive File Max. Size

rcvmaxfilesize

(*5)

1 or more (*5)

Bytes

Clear Unsent File

delreqcpfile

Yes

(*2)

(*6)

Clear Resend Queue File

delresendfile

Yes

(*2)

(*6)

Receive File Lock Standby

rcvfilelockwait

Wait

(*2)

 

Compression Type Selection

comp_selection

C

(*2)

 

Local Host Name

myhostname

 

 

Within 68 bytes

Communication

 

Connect Retry Count

retrycnt

10

0–99999

 

Connect Retry Interval

retrytime

1

0–99999

 

Auto Resend Retry Count

sockerr_autoretry

0

0–9

 

Socket Read Timeout

socktime

3600

10–259200

 

Socket Buffer Size for Data Sending

sndsocksize

0

0,4096–2147483647

 

Socket Buffer Size for Data Receiving

rcvsocksize

0

0,4096–2147483647

 

Service Connect Timeout

srvtime

3600

1–65535

 

HULFT Manager Timeout

admsocktime

3600

10–259200

 

IP Version

ipversion

4

(*2)

 

Queue of Pending Connect

listen

50

1–512

 

Framed Message Transfer Type

proctranstype

Send and Receive Speed Priority Mode

(*2)

 

Security

 

Management Screen Security

admcheck

Disabled

(*2)

 

Password Check

password

No

(*2)

 

Allow Send/Resend Request from Unregistered Host

allowsndreq

Yes

(*2)

 

Allow Post-receive Job Result Inquiry from Unregistered Host

allowpostrjobrslt

Yes

(*2)

 

Allow Job Result Notification Request from Unregistered Host

allowjobrsltntfy

Yes

(*2)

 

Allow Remote Job Execution Request from Unregistered Host

allowrmtjobexe

Yes

(*2)

 

Allow Instant Transfer from Unregistered Host

allowinsttrans

No

(*2)

 

Instant Transfer Receive Root Directory

insttransroot

"itr" directory sibling of HULPATH

Characters

Within 200 bytes

Forced Strong Key Mode

strongkeymode

Disabled

(*2)

 

Transfer-Related File Deletion Mode

trnsfr_file_del

0

(*2)

 

Global

 

Date Format

datefmt

YMD

(*2)

 

HULFT Operation Language

hullang

Value set during installation

(*2)

 

Transfer Test

 

Transfer Preference

ttmode

Test-priority Mode

(*2)

 

Result Handling of Receiving

ttrcvomit

Handle As Unsuccessful End

(*2)

 

Output Receive File

ttrcvfiloutput

No

(*2)

 

Execute Pre-send Job

ttpresndjob

No

(*2)

 

Execute Post-send Job

ttsndjob

No

(*2)

 

Execute Post-receive Job

ttrcvjob

No

(*2)

 

Output Results to Transfer Logs

ttsndrcvlog

Yes

(*2)

 

Logs

 

Log Rotation Record Count

logdelcount

0

0–999999

 

Console Log Size

logsize

999999

1024–102400

999999: unlimited

Output to Event Logs

eventlog

Not selected

(*1)

 

Output to Console Logs

consolelog

All selected

(*1)

 

Console Log Backup

backuplog

Yes

(*2)

 

Operation Log Output Option

oplselect

No

(*2)

 

Operation Log User-specified Character

oplcharacter

 

Alphanumeric characters

Within 8 bytes

Operation Log User ID Output Format

opluseridtype

Down Level Log-on Name

(*2)

 

Operation Log Rotation Size

oplchangesize

0

0–9999

0: unlimited

Operation Log Generations

oplgenerationcount

9999

2–9999

 

Log Size Reduction Mode

logreduction

Output full log

(*2)

 

Log Output Version

logver

V8.4 Header

(*2)

 

Others

 

Job Timeout

jobwtimeout

999999

10–259200

999999: unlimited

Transfer Status Transfer Count

disptranscnt

100

1–100

 

Observe Log Output

-

All selected

(*1)

 

Status Display Selection

statusdisplay

Display All

(*2)

 

HULFT Script Port No.

hsport

(*8)

1–65535

 

Shared Settings by HULFT

 

Path to Location for Cross-Product Sharing

hulsharepath

 

Characters

Within 200
bytes

Local File Lock Mode

localfile_lockmode

Mode 0

(*2)

 

Scheduler

 

Weekly Non-working Days

weekoff

Sunday, Saturday

(*1)

 

Include Holidays in Non-working Days

holiday

Marked

(*1)

 

Scheduling Time

schtime

0

0–23

 

Schedule Process Multiplex Level

schnum

50

1–999

 

Designated Non-working days

-

 

 

 

Holidays

-

(*7)

 

 

Mail Interface

 

Mail Account Name

User

 

Alphanumeric characters

Within 30 bytes

Mail Server Host Name

MailHost

 

Alphanumeric characters

Within 68 bytes

SMTP Port No.

SmtpPort

 

1–65535

 

Full Name

FullName

 

Alphanumeric characters

Within 30 bytes

Domain Name

DomainName

 

Alphanumeric characters

Within 64 bytes

Clustering

 

Management Information Duplication

adjoinadminfile

Yes

(*2)

(*6)

Processing Status Output and Event Log

alertmsgput

Yes

(*2)

(*6)

Processing Status Storage File Count

consolelogcnt

10000

100–1000000

 

Sync Start with Service

startsync

Do Not Sync

(*2)

 

*1

:

For the HULFT Manager Management Console, select the check box.

*2

:

For the HULFT Manager Management Console, click a setting value on the pulldown list.

*3

:

The default value is 'HULFT Encryption Scheme' when HULFT product configuration on the destination host includes HULFT Cipher Option, and 'Other Encryption Scheme' when HULFT product configuration does not include HULFT Cipher Option.

However, if you added HULFT Cipher Option or changed the type of HULFT Cipher Option by updating the Product Key, the default value is not changed. For details, refer to Installation Manual for the destination host.

*4

:

'As Successful End' is set for new installation.

*5

:

9,223,372,036,854,775,808 (The 63rd power of two)

*6

:

The default value is 'Duplicate' or 'Output' for HULFT10 Server grade.

*7

:

Refer to Scheduler Manual for the destination host.

*8

:

HULFT Script Port No. (hsport) has no default value.

If DataSpider Servista is installed, specify a port number for HULFT Script Port No. (hsport).