System Environment Settings list

The fields of the System Environment Settings displayed on the System Environment Settings screen are classified as follows:

Note

You can specify the Shared Settings by HULFT if HULFT10 Enterprise grade is installed.

Table 4.48 System Environment Settings List

Field Name

Tag Name

Default Value

Valid Value

Remarks

Startup

 

Work File Generation Path

tmpdir

Value set during installation

 

Within 200 bytes

Send Daemon Communication Method

sddrequestmethod

Normal socket

(*1)

(*2)

FIFO Path

fifopath

Value set during installation

 

Within 200 bytes (*3)

Command Acknowledge Port No.

sddport

32000

1–65535

 

Receive Port No.

rcvport

30000

1–65535

 

Observe Port No.

obsport

31000

1–65535

 

Send Process Multiplex Level

sndpsnum

10

1–9999

 

Receive Process Multiplex Level

rcvpsnum

0

0–9999

0: unlimited

Pid File Generation Path

piddir

Value set during installation

 

Within 200 bytes

Code Conversion

 

Code Set for Transfer

cs4trnsfr

Value set during installation

(*1)

(*4)

Kanji Code Type

knjcode

Value set during installation

(*1)

(*5)

Standard for Japanese

jistype

83JIS

(*1)

(*4)

JIS Year

jistype

83JIS

(*1)

(*5)

Tab Code Mode

tabchange

Space

(*1)

 

Use Custom Character Table

gaijifile

No

(*1)

 

Handling of Unregistered Custom Characters

gaijierr

Default Value

(*1)

 

Code Conversion Mode

codechangemode

Mode 0

(*1)

 

Instant Transfer Code Converting Side

insttranscodcnv

Receiving Side

(*1)

(*2)

Attribute Conversion

 

Pack Zone Conversion

pschg

Mode 0

(*1)

 

Sign for ASCII

psascii

Mode 1

(*1)

 

Sign for EBCDIC

psebcdic

Mode 1

(*1)

 

X Type Conversion

xmode

Mode 0

(*1)

 

Send and Receive

 

Encryption Scheme

ciphertype

(*6)

(*1)

 

Receive Open Mode

rcvfilewait

Mode 1

(*1)

 

Receive Multiplex Level Over Retry

rcvover_rty

Do Not Retry,
and Give Error

(*1)

 

Transfer Group Check

tgrpchk

No

(*1)

 

Dynamic Parameter Specification

dynparam

Enable Dynamic Specification

(*1)

 

Message Dynamic Parameter Specification

msgdynparam

Always Replace Messages and Variables

(*1)

 

Send Transfer Error Recovery

enderrmode

As Unsuccessful End

(*1)

 

Criteria to Delete Resend Queue

resenddel

Mode 1

(*1)

 

Receive File Max. Size

rcvmaxfilesize

0

0 or more (*7)

0: unlimited

Local Host Name

myhostname

The name of host you specified when you install HULFT

 

(*8)

Compression Type Selection

comp_selection

C

(*1)

 

Communication

 

Connect Retry Count

retrycnt

5

0–9999

 

Connect Retry Interval

retrytime

20

0–9999

 

Auto Resend Retry Count

sockerr_autoretry

0

0–9

 

Socket Read Timeout

socktime

3600

10–259200

999999: unlimited

Socket Buffer Size for Data Sending

sndsocksize

0

0,4096–2147483647

 

Socket Buffer Size for Data Receiving

rcvsocksize

0

0,4096–2147483647

 

Observe Timeout

obssocktime

86400

10–259200

999999: unlimited

IP Version

ipversion

4

(*1)

 

Framed Message Transfer Type

proctranstype

Send and Receive Speed Priority Mode

(*1)

 

Security

 

Management Screen Security

admcheck

Disabled

(*1)

 

Password Check

passwdcheck

No

(*1)

 

Operation Log Output Option

oplselect

No

(*1)

 

Operation Log Rotation Size

oplchangesize

0

0–9999

0: unlimited

Operation Log Generations

oplgenerationcount

9999

2–9999

 

Forced Strong Key Mode

strongkeymode

Disabled

(*1)

(*2)

Transfer-Related File Deletion Mode

trnsfr_file_del

0

(*1)

 

Allow Send/Resend Request from Unregistered Host

allowsndreq

Yes

(*1)

(*2)

Allow Post-receive Job Result Inquiry from Unregistered Host

allowpostrjobrslt

Yes

(*1)

(*2)

Allow Job Result Notification Request from Unregistered Host

allowjobrsltntfy

Yes

(*1)

(*2)

Allow Remote Job Execution Request from Unregistered Host

allowrmtjobexe

Yes

(*1)

(*2)

Allow Instant Transfer from Unregistered Host

allowinsttrans

No

(*1)

(*2)

Instant Transfer Receive Root Directory

insttransroot

"itr" directory sibling of HULPATH

 

Within 200 bytes (*2)

Global

 

Date Format

datefmt

Value set during installation

(*1)

 

HULFT Operation Language

hullang

Value set during installation

(*1)

 

Transfer Test

 

Transfer Preference

ttmode

Test-priority Mode

(*1)

 

Result Handling of Receiving

ttrcvomit

Handle As Unsuccessful
End

(*1)

 

Output Receive File

ttrcvfiloutput

No

(*1)

 

Execute Pre-send Job

ttpresndjob

No

(*1)

 

Execute Post-send Job

ttsndjob

No

(*1)

 

Execute Post-receive Job

ttrcvjob

No

(*1)

 

Output Results to Transfer Logs

ttsndrcvlog

Output

(*1)

 

Others

 

Utility Timeout

utlwait

60

10–259200

999999: unlimited

Job Timeout

jobwtimeout

999999

10–259200

999999: unlimited

Log Rotation Record Count

logdelcount

0

0–999999

 

Status Display Selection

statusdisplay

Display All

(*1)

 

HULFT Identifier

hulcharacter

 

Alphanumeric characters

Within 8 bytes

HULFT Script Port No.

hsport

(*9)

1–65535

(*10)

Trace Output Version

tlogver

Output the Trace Log (V8 header)

(*1)

 

Trace Output Mode

tlogmode

Output Only Unsuccessful Log Records

(*1)

(*3)

Log Size Reduction Mode

logreduction

Output full log

(*1)

(*2)

Output to Trace Logs

tracelog

Only "Error" is selected

(*11)

(*2)

Output to System Logs

syslog

Not selected

(*11)

(*2)

Trace Output File Name

tlogfile

HULPATH/trace
(*12)

 

Within 256 bytes

Trace Output File Size

tlogsize

10

1–1024

 

Shared Settings by HULFT

 

Path to Location for Cross-Product Sharing

hulsharepath

HULPATH

 

Within 200 bytes

Local File Lock Mode

localfile_lockmode

Mode 0

(*1)

 

*1

:

For the HULFT Manager Management Console, click a setting value on the pulldown list.

*2

:

These fields are displayed when HULFT Manager connects to HULFT Ver.8.4 or higher.

*3

:

These fields are displayed when HULFT Manager connects to HULFT lower than Ver.8.4.

*4

:

This field is displayed when HULFT Manager connects to HULFT Ver.8.1 or higher.

*5

:

This field is displayed when HULFT Manager connects to HULFT lower than Ver.8.1.

*6

:

The default value is 'HULFT Encryption Scheme' when HULFT product configuration on the destination host includes HULFT Cipher Option, and 'Other Encryption Scheme' when HULFT product configuration does not include HULFT Cipher Option.

However, if you added HULFT Cipher Option or changed the type of HULFT Cipher Option by updating the Product Key, the default value is not changed. For details, refer to Installation Manual for the destination host.

*7

:

9,223,372,036,854,769,999

*8

:

There is no default value for HULFT for NSK.

*9

:

If HULFT product configuration on the destination host includes DataSpider Servista, the value is '7700'. If the configuration does not include DataSpider Servista, the value is not set.

*10

:

This field is displayed only if you install DataSpider Servista on the destination host.

*11

:

For the HULFT Manager Management Console, select the check box.

*12

:

HULPATH

The directory which stores the environment settings files used by HULFT.