During receiving-side transferring

Table D.3 During receiving-side transferring

Trouble

Cause and Measures

Cannot receive due to socket error

Make sure that PING command to and from the remote host works properly.

Make sure that the specification of the Host Information of HULFT is correct.

Make sure that there is no mistake in the registration of TCP/IP host table of IBM i.

Cannot receive due to file-related error

Make sure that there is no mistake in the registration of the Receive Management Information.

Make sure that the file to be received is not used by another job.

Cannot receive due to error code 809

HULFT has received the data that is longer than the value of the Record Length registered in the Receive Management Information. Check the data length and the record length of the Receive file.

Cannot receive due to error code 832

Make sure that the library name that you specify for the File Name of the Receive Management Information actually exists.

Cannot receive due to error occurred on sending side

An error has occurred on a sending host. Check the host on the sending side.

Program ended unexpectedly

Make sure that the system value QJOBMSGQFL (Job message queue full action) of the environment in which HULFT runs is set to "*WRAP".

Make sure that the JOBMSGQFL (Job message queue full action) attribute of the job description that HULFT uses is NOT set to "*NOWRAP".