Notes about updating
If the system configuration is one listed in the table below, clients are disabled after an upgrade installation has been performed on HULFT-HUB Server. In such a case, you must take one of the following actions after the update installation of HULFT-HUB Server has been completed:
-
Use a HULFT-HUB Manager whose revision is the same as or later than the revision of the HULFT-HUB Server to obtain the management information.
-
Use the management information synchronization utility to synchronize the management information on HULFT-HUB Server.
Table 10.1 Configurations that require actions after an update installation
|
Configuration before migration |
Configuration after migration |
||
|---|---|---|---|
|
Client |
HULFT-HUB Server |
Client |
HULFT-HUB Server |
|
HULFT for Windows version 7.2.0 to a version earlier than 7.3.0 |
Version earlier than 3.1.0 |
HULFT for Windows version 7.2.0 to a version earlier than 7.3.0 |
Version 3.1.0 or later |
|
HULFT for UNIX/Linux version 7.2.0 to a version earlier than Ver.7.3.0 |
Version earlier than 3.1.1 |
HULFT for UNIX/Linux version 7.2.0 to a version earlier than Ver.7.3.0 |
Version 3.1.1 or later |
|
HULFT version 7.3.0 or later |
Version earlier than 3.2.1 |
HULFT version 7.3.0 or later |
Version 3.2.1 or later |
If the system configuration is one listed in the table below, after upgrade installation of HULFT-HUB Server, if the Send Management Information or the Receive Management Information is updated from HULFT-HUB, the value of Cipher Key may be deleted. In such a case, you must take one of the following actions after the update installation of HULFT-HUB Server has been completed:
-
Use a HULFT-HUB Manager whose revision is the same as or later than the revision of the HULFT-HUB Server to obtain the Send Management Information and the Receive Management Information.
-
Use the management information synchronization utility to synchronize the Send Management Information and the Receive Management Information on HULFT-HUB Server.
Table 10.2 Configurations that require actions after an update installation
|
Configuration before migration |
Configuration after migration |
||
|---|---|---|---|
|
Client |
HULFT-HUB Server |
Client |
HULFT-HUB Server |
|
HULFT for Windows Ver.8.4.x |
Earlier than Ver.3.9.0 |
HULFT for Windows Ver.8.4.x |
Ver.3.9.0 or later |
|
HULFT for UNIX/Linux Ver.8.4.x |
HULFT for UNIX/Linux Ver.8.4.x |
||
|
HULFT for zOS Ver.8.4.x |
HULFT for zOS Ver.8.4.x |
||
|
HULFT for IBMi Ver.8.4.x |
HULFT for IBMi Ver.8.4.x |
||
For HULFT-HUB Server Ver.3.10 and later, connection with the following clients is not supported:
-
Clients whose host type is "K"
-
Versions earlier than HULFT Ver.7
Additionally, the information that can be managed from HULFT-HUB Server Ver.3.10 and later has been modified.
Accordingly, when you perform a version upgrade from a version earlier than HULFT-HUB Server Ver.3.10 to Ver.3.10 or later, perform the following operations:
-
Obtain the management information and synchronize the management information that is stored on HULFT-HUB Server and the management information of HULFT.
-
If clients whose host type is "K" exist as registered clients, delete them.
-
If clients whose version is earlier than HULFT7 exist as registered clients, delete them.