HULFT-29829
If you send files from HULFT in a state where the Transfer Processing Multiplex Level (TransRlyMax) of HULFT-HUB Server has been exceeded, a socket error may be detected instead of Multiplex Level Over
- Phenomenon
-
If you send files from HULFT for Windows in a state where the Transfer Processing Multiplex Level (TransRlyMax) of HULFT-HUB Server has been exceeded, a socket error may be detected instead of Multiplex Level Over.
When this error occurs, the following error code is output to the send log:
Send log
- Status code:
-
364732
- Detail code:
-
10054
- Description:
-
The Receive processing failed.
- Measure:
-
The socket may be disconnected. Refer to Detail Code.
- Severity level
-
C: medium
- Affected versions
-
From Ver.3.5.0 to Ver.3.9.3
- Modified version
-
Ver.3.10.0
- Condition to reproduce
-
This phenomenon may occur when you perform a relay transfer from HULFT for Windows to HULFT-HUB Server while the transfer relay multiplex level of HULFT-HUB Server is full.
- Alternative workaround
-
None
- Status description
-
If the conditions to reproduce are met, the error code for Multiplex Level Over is output to the send log.
Send log
- Status code:
-
364450
- Detail code:
-
00516