HULFT-29829

If you send files from HULFT in a state where the Transfer Processing Multiplex Level (TransRlyMax) of HULFT-HUB Server has been exceeded, a socket error may be detected instead of Multiplex Level Over

Phenomenon

If you send files from HULFT for Windows in a state where the Transfer Processing Multiplex Level (TransRlyMax) of HULFT-HUB Server has been exceeded, a socket error may be detected instead of Multiplex Level Over.

When this error occurs, the following error code is output to the send log:

 

Send log

Status code:

364732

Detail code:

10054

Description:

The Receive processing failed.

Measure:

The socket may be disconnected. Refer to Detail Code.

Severity level

C: medium

Affected versions

From Ver.3.5.0 to Ver.3.9.3

Modified version

Ver.3.10.0

Condition to reproduce

This phenomenon may occur when you perform a relay transfer from HULFT for Windows to HULFT-HUB Server while the transfer relay multiplex level of HULFT-HUB Server is full.

Alternative workaround

None

Status description

If the conditions to reproduce are met, the error code for Multiplex Level Over is output to the send log.

 

Send log

Status code:

364450

Detail code:

00516